OMEGA AUTOMATICS 2020 v3.0.2 24
Option for activating the door when it is pushed manually. (1_ON,
0_OFF)
Option for the door to reactive while the door is in closing cycle.
(1_ON, 0_OFF)
Time of opening cycle (in secs)
Time of closing cycle (in secs)
Time of latching cycle (in secs)
Changing value from 1 to 3 provides factory reset
Time how long will stay open when used as push to activate
Separated opening time that moves the door in different speed with
no obstruction
Separated opening speed that follows the strike time strike speed
and strike time always used together
Reduces or increase the kick out of latch lower the value-stronger
the kick
Changed from 0 to 1 it will reverse read switches
Changes operating mode of the controller 1-Regular, 2-Washroom,
3-Access control
Changes the strike from fail safe to fail secure
Use only on HD model for length of power close
Speed force of the door when it engages power closing (only HD
mode)
14. Re-Learn
1. Once the display indicate door closed press menu touch button and scroll down to calibrate. Press SEL touch button
the display will indicate force relearn.
2. Press SEL touch button for relearn on next activation. Exit parameter mode when the display indicate door closed
press act touch. Door operator will perform new learning.
15. Changes in software version
V1.8- Standard Access control, washroom, motor revers
V2.0- Safety Sensor Wiring diagram
V2.3- Encoder, safety sensor, ACT DLY, preload time, preload speed, overload to 99 bypass.