Level Functions Allowed
1 Primary Master can view log and set time, assign other user codes, all system functions
2 Secondary Master, same as primary Master except cannot change the primary Masters code
3 User, can arm and disarm only
4 Limited user, same as level 3, except can disarm the system only if it was armed by another
user with level 4 authority (cannot disarm if armed with user of higher authority level).
4/6-DIGIT USER CODES
The system supports either 4- or 6-digit user codes. A bit option in Submode 1, Question 12, Location 3
selects if the user codes are to be 4 or 6 digits in length for the entire system. The default user code for
the master is 1234 with an authority level of 1. The system is defaulted to 4-digit user/installer code. If
the bit is set in installer mode, each currently programmed code will change to six digits by adding a
00" before the known 4-digit code.
For example, if 4-digit codes are being changed to 6 digits and a user code was 1-2-3-4, it will become 0-
0-1-2-3-4. Conversely, if the user code length was 6, and it is changed back to 4 digits, the code 1-2-3-4-
5-6 will become 3-4-5-6.
Once 6-digit user codes is selected, new codes entered can be any combination of 6 digits.
NOTE:
Selecting 6-digit user codes also affects the installer code by adding 00 to the code (default
installer code 2468 becomes 002468). Use Question 00 to enter a new installer code.
TO ADD OR CHANGE USERS:
Press [CODE] + MASTER USER CODE + USER NO. + NEW USER CODE + AUTHORITY LEVEL
where:
[CODE] [CODE] button on keypad.
MASTER USER 4- or 6-digit* Master User code (user with authority level 1 or 2)
USER NO. Desired user number to be programmed (0132).
NEW USER CODE 4- or 6-digit* user code for the new user. Valid digits are 09.
AUTHORITY LEVEL The desired authority level for the new user.
*(Depending on the whether the system is set for 4- or 6-digit security codes)
Example: Define user number 03 with a code of 7493 and authority level 3. (Assume Master code is
1234) = CODE 1234 03 7493 3
An acknowledgment (steady tone) verifies a successful user code programming. A negative acknowledgment
(4 short tones) indicates unsuccessful programming. If additional user programming is necessary, repeat the
procedure listed above. If a dialing format is programmed that transmits opening/closing by user ID, each
user will report their user number.
ASSIGNING PARTITIONS AND PAGER OPEN/CLOSE REPORTS TO USERS
Users are automatically enabled for the partition where their code was added. You can also allow users
to access other partitions and/or enable open/close pager reports for a user by using the #7 command as
follows:
[#] + [7] + MASTER USER CODE + USER NO. + [1], [2], or [4]