OMNI-624/OMNI-624EU Installation and Setup Guide
1-2
• Upload/download and remote commands
• 3 methods of uploading/downloading: PC,
operator-initiated, and unattended
• Paging (audio format) capabilities
• Auto-arming at a specific time of day with
capability to arm in either Away, Stay, or
Instant modes
• Dual entry timers
• Fire zone reset through keypad
• Glassbreak reset through keypad
• Bell Test, Low Battery Test, AC loss and
communications failure
• Input power: 16.5VAC, 25VA; 12VDC, 4-7AH
• Output power: 12VDC, 500mA
• Bell output power: 12VDC, 1A
Special Notes
!
IMPORTANT - Failure to install and program this unit in accordance with the UL
requirement is a violation of the listing mark. For more information on UL Listings,
contact Underwriters Laboratories, Progress Department, 333 Pfingsten Road,
Northbrook, IL 60062.
UL Listings
The OMNI-624 is the Residential (Household) version of the control panel, and has been Listed by
Underwriters Laboratories for the following applications:
• UL 1023 Household Burglary
• UL 985 Household Fire Warning
FCC Registration Number: 5GBUSA-44003-AL-E
References to Programming Questions
Programming questions are grouped into 4 installer programming submodes, as follows:
1 – System Options
2 – Zone and Report Code Programming
3 – Wireless Zone/Keyfob Programming
4 – Zone Descriptor Programming
Throughout this manual, programming question references without a submode designation pertain to
questions in submode 1 (system options). Programming questions for other submodes include the
appropriate submode number.