87
On the Omnia-3net/drm typing sysparas <enter> displays the following table:
1) Input Source [ANALOG] 2) Analog Gain [0]
3) Input Left [0.0dB] 4) Input Right [0.0dB]
5) Output Left [+4.0dB] 6) Output Right [+4.0dB]
7) SCA Level [-20.0dB] 8) Composite 1 [3.60 V]
9) Pilot Level ['n/a'] 10) Phase Adjust ['n/a']
11) Deemphasis ['n/a'] 12) Preemphasis ['n/a']
13) Analog Phase [1] 14) LED Source [0]
15) Backlight [70] 16) Contrast [50]
17) Headphones [-10.0dB] 18) Separation ['n/a']
19) Editing Mode [EXPERT] 20) Current State [ENABLED]
21) Composite 2 [3.60 V] 22) Input Phase [NORMAL]
23) Preemphasis ['n/a'] 24) Ctrl Port Baud [19200]
25) Mono Mode [Stereo] 26) Asym Mod ['n/a']
27) Tilt Eq ['n/a'] 28) Tilt Freq ['n/a']
29) HP Filter ['n/a'] 30) Meta ['n/a']
31) LPF Freq ['n/a'] 32) LPF Freq [16kHz]
33) BS412 ['n/a'] 34) Ref. Headroom ['n/a']
35) Ave. Power ['n/a'] 36) WB AGC ['n/a']
37) Phase Rot. ['n/a']
A value of ‘n/a’ indicates that this parameter is not applicable to the net style.
Setting New Syspara Values
To find the new value you wish to use for a particular Syspara:
sysparavalues <syspara index #> Lists all the possible values for any parameter.)
Example: sysparavalues 3 <enter> Displays a table listing the possible Input Left values.
To set a new value for a Syspara:
syspara <syspara index #>[<sysparavalue index #>]
To reset all System parameters back to their factory defaults:
sysdefaults Restores the system attributes back to their factory defaults.
To save all System settings to the rear-panel memory card.
syssave Saves the system attributes to the Omnia PC Card.
To load the saved setting from the rear-panel memory card:
sysload Loads the system attributes from the currently inserted Omnia PC Card.