ENGLISH
• 5 •
REPLACEMENT PARTS
1 144802 Pressure Relief Button Kit (not visible)
2 154371 Blue cap
3 151121 O-ring
4 153219 Blue housing sump
5 150539 Housing wrench (not shown)
6 150580 Screw Kit (not shown)
PERFORMANCE DATA
SFM2 Series B with GAC1 Series B Cartridge
Important Notice: Read this performance data and compare
the capabilities of this system with your actual water treatment
needs. It is recommended that, before installing a water
treatment system, you have your water supply tested to
determine your actual water treatment needs.
This system has been tested according to NSF/ANSI 42 for the
reduction of the substances listed below. The concentration
of the indicated substances in water entering the system was
reduced to a concentration less than or equal to the permissible
limit for water leaving the system, as specified in NSF/ANSI 42.
SFM2 Series B with GAC1 Series B Cartridge
Substance
Influent Challenge
Concentration
Reduction
Requirements
Average
Reduction
Standard 42 Aesthetic Effects
Chlorine 2.0 mg/L ± 10% ≥50% 85%
Flow Rate- 1.0 gpm (3.8 Lpm) Capacity= 2,000 gallons (7,600 L ) or 12 months
Testing was performed under standard laboratory conditions, actual performance
may vary.
For replacement parts contact your local OMNIFILTER retailer or
call OMNIFILTER Customer Service at 800.937.6664.
2
1
3
4