OM26KCS, OM32KCS, OM36KCS
Water Softening System
INSTALLATION INSTRUCTIONS
English . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 2-22
Repair Parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 13
OM26KCS, OM32KCS, OM36KCS
Sistema de ablandamiento de agua
INSTRUCCIONES DE INSTALACIÓN
Español . . . . . . . . . . . . . . . . . . . . . . . . . . Páginas 23-43
Piezas de repuesto . . . . . . . . . . . . . . . . . . . . . Página 32
OM26KCS, OM32KCS, OM36KCS
Système d'adoucissement d'eau
DIRECTIVES D'INSTALLATION
Français . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 44-64
Piéces de Rechange . . . . . . . . . . . . . . . . . . . . . Page 50
293 Wright Street • Delavan, WI 53115
Phone: 800.937.6664
www.omnilter.com
©2011 OMNIFILTER • Printed in U.S.A. 4001568 Rev B DE11
Tools and Fittings Required
Pipe Cutter
Tubing Cutter
File
Pliers
Tape Measure
Soldering Tools
Lead Free Solder
Bucket
Towel
Teon Pipe Tape
Adjustable Wrench
Tube 100% Silicone Grease
For further operating, installation, maintenance,
parts or assistance:
Call OMNIFILTER Customer Service at:
800.937.6664
Para obteners información sobre el
funcionamiento, la instalación, el mantenimiento,
las piezas o para obtener asistencia:
Comuníquese con el Servicio de atención
al cliente de OMNIFILTER al: 800.937.6664
Pour de plus amples renseignements sur le
fonctionnement, l'installation, l'entretien, les
pièces, ou pour avoir de l'aide,
appelez le service clientèle OMNIFILTER à :
800.937.6664
Tested and Certied by WQA to
NSF/ANSI Standard 44 for softener
performance & 372 for "lead free"
compliance.
T
E
S
T
E
D
A
N
D
C
E
R
T
I
F
I
E
D
U
N
D
E
R
I
N
D
U
S
T
R
Y
S
T
A
N
D
A
R
D
S
Herramientas y coples requeridos
Cortadora de tubería
Cortadora de tubos
Lima
Pinzas
Cinta métrica
Herramientas para soldar
Soldadura sin plomo
Cubeta
Toalla
Cinta de Teon (teón)
para tuberías
Llave inglesa con pasador
ajustable
Grasa 100 % siliconada
para tubos
Outils et accessoires requis
Coupe-tuyau
Coupe-tube
Lime
Pinces
Mètre ruban
Outils à souder
Soudure sans plomb
Seau
Serviette
Bande adhésive pour tuyau
en Teon
Clé ajustable
Graisse de silicone à 100 %
en tube
Testé et certié par WQA conforme à
la norme 44 pour la performance de
l'adoucisseur et à la norme 372 pour
conformité d'exemption de plomb de
NDF/ANSI.
T
E
S
T
E
D
A
N
D
C
E
R
T
I
F
I
E
D
U
N
D
E
R
I
N
D
U
S
T
R
Y
S
T
A
N
D
A
R
D
S
Probado y certicado por WQA de
acuerdo con la Norma 44 de NSF/
ANSI con respecto al rendimiento
del ablandador y 372, en cuanto
al cumplimiento “sin plomo”.
T
E
S
T
E
D
A
N
D
C
E
R
T
I
F
I
E
D
U
N
D
E
R
I
N
D
U
S
T
R
Y
S
T
A
N
D
A
R
D
S

Table of Contents

Questions and Answers

  • D
    Daniel SawyerAug 18, 2025
    What to do if the Omnifilter Water Filtration Systems salt tank overflow?
    • R
      richardwoodsAug 18, 2025
      If the Omnifilter Water Filtration Systems salt tank is overflowing, it could be due to a loose salt line connection. Make sure all salt line connections are tight. Another possible cause is a drain line restricted with debris; in this case, you should clean the drain control.
  • D
    dadkinsAug 21, 2025
    Why won't my Omnifilter OM26KCS Water Filtration Systems control recharge automatically?
    • M
      meredithramosAug 21, 2025
      If your Omnifilter Water Filtration Systems control is not recharging automatically, ensure the AC adapter or motor is connected to power. If it is, a defective motor could be the issue, requiring a replacement. Also, the meter might be clogged with debris, which means you should remove and clean it. Note that the unit will recharge every 7 days regardless.
  • M
    Maureen GuerreroAug 23, 2025
    What to do if there is hard water leakage after recharge with Omnifilter OM26KCS Water Filtration Systems?
    • G
      Glenn TurnerAug 23, 2025
      If you notice hard water leakage after a recharge with your Omnifilter Water Filtration Systems, it could be due to several reasons. First, ensure that the correct salt dosage was set and repeat the recharge. If the issue persists, check for a leaking external bypass valve and replace it if necessary. Finally, inspect the O-ring around the riser pipe for damage and replace it if needed.
  • J
    John WoodsAug 26, 2025
    Why won't the Omnifilter OM26KCS Water Filtration Systems valve draw brine?
    • T
      Tammy BurnsAug 27, 2025
      If the valve in your Omnifilter Water Filtration Systems isn't drawing brine, check for a restricted drain line and remove any obstructions. Also, the injector might be plugged, so clean the injector and screen. Debris preventing the valve discs from closing can also cause this issue; remove any foreign matter from the valve discs.
  • M
    Michael HuntAug 28, 2025
    Why is there no conditioned water after recharge in my Omnifilter OM26KCS?
    • M
      Melanie WrightAug 28, 2025
      If you're not getting conditioned water after a recharge with your Omnifilter Water Filtration Systems, the salt tank may be empty, so add salt. Alternatively, the injector could be plugged. In this case, you should clean the injector and screen.
  • R
    richard30Aug 30, 2025
    Why does my Omnifilter OM26KCS Water Filtration Systems run out of conditioned water between recharges?
    • A
      Amy SanchezAug 30, 2025
      If your Omnifilter Water Filtration Systems is running out of conditioned water between recharges, the control may be improperly programmed. Verify the salt dosage setting.
  • R
    Rickey NielsenSep 2, 2025
    What to do if I see flowing or dripping water at the drain or salt line after recharge in Omnifilter OM26KCS?
    • E
      Emily JacksonSep 2, 2025
      If you observe flowing or dripping water at the drain or salt line after a recharge with your Omnifilter Water Filtration Systems, debris may be preventing the #4 valve disc from closing. Remove any debris. Alternatively, the #4 valve disc may be worn and need replacement.
  • G
    George MirandaSep 5, 2025
    Why does Omnifilter OM26KCS Water Filtration Systems backwash or rinse at an excessively low or high rate?
    • D
      Daniel JenningsSep 5, 2025
      If your Omnifilter Water Filtration Systems is backwashing or rinsing at an excessively low or high rate, it could be due to a missing drain line flow control. Install a drain line flow control. Another possible reason is a restricted drain line; remove the restriction to resolve this.
  • S
    Scott MaldonadoSep 7, 2025
    Why doesn't the flow indicator on my Omnifilter OM26KCS control display service flow?
    • M
      Matthew CampbellSep 7, 2025
      If the flow indicator on your Omnifilter Water Filtration Systems control isn't displaying service flow, check if the bypass valve is in the bypass position and remove it from bypass. Also, the meter cable might be dislodged from the valve; fully insert the meter cable into the valve. Another cause may be that the meter is clogged with debris, so remove and clean the meter.
  • J
    Jeff DudleySep 10, 2025
    Why is the salt draw intermittent in my Omnifilter OM26KCS?
    • T
      Thomas CobbSep 10, 2025
      If you're experiencing intermittent salt draw with your Omnifilter Water Filtration Systems, low water pressure could be the cause. Make sure to maintain a minimum of 20 psi (1.3 bar) feed.

Omnifilter OM26KCS Specifications

General IconGeneral
ModelOM26KCS
CategoryWater Filtration Systems
Filter MediaActivated Carbon
Maximum Pressure100 PSI
Weight5 lbs
Micron Rating5 microns
InstallationDIY
Filter Life6 months
Operating Temperature40-100°F
Contaminants ReducedSediment
ReducesSediment
TypeWhole House Water Filter

Related product manuals