13 B5WC Built- In Color Sensor User's Manual (E612- E1- 01)
7 Installation Method
1. This sensor can be mounted in two directions, X and Y. Refer to the product specifications for details of
mounting.
* Use M3 screws, spring washers, and flat washers and tighten with torque of 0.54(Nā‹…m).
2. The structure of this sensor should be designed with equipment to prevent ambient light from entering.
If the sensor's light-emitting or light-receiving block must be exposed to the outside of the equipment
for application purposes, the effect of ambient light can be reduced by installing the sensor in such a
way that no ambient light enters from the light-receiving path direction. As shown in the figure below,
the emitting and receiving light paths of this sensor form a V shape. Therefore, it is necessary to
evaluate the sensor sufficiently by considering the direction of sensor installation to prevent ambient
light from entering from this direction.
3. This sensor is neither waterproof nor oil resistant. You need to design the structure of the equipment to
prevent water, oil, or chemicals from pouring on the sensor. For detailed precautions, refer to the
precautions for safe use and precautions for correct use described in the specifications and datasheet.
Receiving light path
Emitting light path
Ambient light