1
Downloading the project
In the Solution Explorer at the upper
right of the Power PMAC IDE window
,
right-click the project name and select
Build and Download All Programs to
build and download all programs.
T
ransfer alone will not save the
project to the PMAC.
If the power to the PMAC is switched
OFF, the transferred project is dis-
carded.
2
Make sure that there are no errors in
the Output tab page.
If the transfer failed, check the error
information in the Output tab page.
If there is a program error
, review the
program.
If the error is caused by the Ether-
Net/IP settings, return to
3-4 PMAC
EtherNet/IP Settings on page 3-16
and check the settings to see if they
are correct.
3
Confirm that there are no errors, and
then save the project to the PMAC.
Execute the save command from the
T
erminal.
By executing the save command, the
downloaded project is stored in the
PMAC. Use this operation to save
the settings that are executed auto-
matically when the power supply to
the PMAC is turned ON.
4
Enabling EtherNet/IP (Restart)
Execute the $$$ command from the
Terminal. The EtherNet/IP settings are
enabled when the PMAC restarts using
the downloaded project.
3 EtherNet/IP Connection Procedures
3-20
CK3E/CK3M/CK5M Series EtherNet/IP Connection Guide (O903)

Other manuals for Omron CK3E Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron CK3E Series and is the answer not in the manual?

Omron CK3E Series Specifications

General IconGeneral
BrandOmron
ModelCK3E Series
CategoryController
LanguageEnglish

Related product manuals