5E3F2
Engineering Data (Typical)
Operating Range (typical)
Through-beam Models (axial)
E3F2-7@4-@
Retro-reflective Models (axial)
E3F2-R4@4@-@ (polarizing)
Retro-reflective Models (radial)
E3F2-R2R@41-@ (polarizing)
and reflectors
Diffuse-reflective Models (axial)
E3F2-DS10@4-@ (wide-beam type)
Diffuse-reflective Models (axial)
E3F2-DS30@4-@
Diffuse-reflective Models (radial)
E3F2-DS30@41-@
Diffuse-reflective Models (axial)
E3F2-D1@4-@
0
01 23 456789
Distance X (m)
- 250
- 200
- 150
- 100
-50
50
100
150
200
250
Distance Y (mm)
X
Y
Reflector
Typical sensing distance
E39-RS3
E39-R1S
E39-R40
E39-R7
E39-R8
0.5 1 1.5 2 2.5 30
0
50
100
–50
–100
Distance Y (mm)
Distance X (m)
43.5
typical sensing distances:
E39-R1: 2.4 m
E39-R7: 2.7 m
E39-R8: 3.1 m
X
Y
Reflector
20 40 60 80 100 1200
0
5
10
15
–5
–10
–15
Distance Y (mm)
Distance X (mm)
140
white paper
(50 x 50 mm)
X
Y
Object
100 200 300 400 500 6000
0
10
20
30
40
–10
–20
–30
–40
Distance Y (mm)
Distance X (mm)
Sensing distance adjustable
between 0 and 550 mm
Sensitivity adjusted to maximum
Sensitivity adjusted to 400 mm
white paper
(100 x 100 mm)
X
Y
Object
100 200 300 400 5000
0
10
20
30
40
–10
–20
–30
–40
Distance Y (mm)
Distance X (mm)
Sensitivity adjusted to 390 mm
White paper (90% reflectivity)
Sensing object:
100 x 100 mm
X
Y
Object
100
80
60
40
20
0
-20
-40
-60
-80
-100
0 200 400 600 800 1000 1200 1400 1600
Distance X (mm)
Distance Y (mm)
Sensing object:
300 x 300 mm
X
Y
Object