Mounting End Plate (PFP-M)
Depending on how it is mounted, an Amplifier Unit may move
during operation. In this case, use an End Plate.
Before mounting an End Plate, remove the clip from the master
Amplifier Unit using a nipper or similar tool.
The clip can also be removed using the following mechanism,
which is incorporated in the construction of the section under-
neath the clip.
1. Insert the clip that is to be removed into the slit underneath
the clip on another Amplifier Unit.
2. Remove the clip by rotating the Amplifier Unit.
Pull Strengths for Connectors (Including Cables)
E3X-CN11: 30 N max.
E3X-CN12: 12 N max.
Reflector
Use of E39-R3 Reflector
Use detergent, etc., to remove any dust or oil from the surfaces
where tape is applied. Adhesive tape will not be attached properly
if oil or dust remains on the surface.
TheE39-R3cannotbeusedinplaceswhereitisexposedtooilor
chemicals.
E39-F32
@
Protective Spiral Tubes
Insert a fiber to the Protective Spiral Tube from the head connec-
tor side (screwed) of the tube.
Push the fiber into the Protective Spiral Tube. The tube should be
straight so that the fiber is not twisted when inserted. Then turn
the end cap of the spiral tube.
Secure the Protective Spiral Tube on a suitable place with the
attached nut.
Use the attached saddle to secure the end cap of the Protective
Spiral Tube. To secure the Protective Spiral Tube at a position
other than the end cap, apply tape to the tube so that the portion
becomes thicker in diameter.
E39-F10 Fiber Connector
Mount the Fiber Connector as shown in the following illustrations.
The Fiber Units should be as close as possible when they are
connected.
Sensing distance will be reduced by approximately 25% when
fibers are connected.
Only 2.2-mm-dia. fibers can be connected.
Clip
Rotate
Fiber Unit
Protective Spiral
Tu be
Protective Spiral
Tu be
Fiber Unit
Mounting panel
Hexagon clamping nut
Fiber Unit
Toothed washer
Protective Spiral
Tube
Saddle
End cap
Tu be
Splice
Retention unit
Retention unit
Fiber Unit
Fiber Unit
Fiber Unit
Fiber Unit

Related product manuals