F3SJ-A
3
Accessories (Sold separately)
Single-Ended Cable (2 cables per set, one for emitter and one for receiver) *
For wiring with safety circuit such as single safety relay, safety relay unit, and safety controller
* The cable for emitter and the cable for receiver are available separately. Add '-L' for emitter or '-D' for receiver to the end of the model number when you order.
Single-Ended Cable for Emitter: F39-JD@A-L, Single-Ended Cable for Receiver: F39-JD@A-D
Note: To extend the cable length to 20 m or more, add the F39-JD@B Double-Ended Cable.
Example: When using a cable of 30 m, connect the F39-JD10A Single-Ended Cable with the F39-JD20B Double-Ended Cable.
Double-Ended Cable (2 cables per set, one for emitter and one for receiver) *
Control unit for connection with F3SP-B1P, to extend the length under series connection (*)
* The cable for emitter and the cable for receiver are available separately. Add '-L' for emitter or '-D' for receiver to the end of the model number when you order.
Double-Ended Cable for Emitter: F39-JD@B-L, Double-Ended Cable for Receiver: F39-JD@B-D
Note: To extend the cable length to 20 m or more, use the Double-Ended Cables in combination.
Example: When using a cable of 30 m, connect the F39-JD10B Double-Ended Cable with the F39-JD20B Double-Ended Cable.
Power cable (included in the main unit. 2 cables per set, one for emitter and one for receiver)
Note: This product is for F3SJ-A only.
Series-connection Cable (2 cables per set, for emitter and receiver)
*1. This product is for F3SJ-A only.
*2. For series connection with minimum length, use F39-JJR06L or F39-JJR15L.
*3. When using the F39-EJ@@@@-L/D Water-resistant Case in series connection configurations, use the special series connection cables for the Water-resistant Case.
Refer to page 73 for details.
Note: The Double-Ended Cable (up to 15 m: F39-JD15B) can be added to extend the cable length between the series-connected sensors.
Cable length between sensors: 15 m max. (not including series connection cable (F39-JJR3W or F39-JJR@L) and power cable)
Appearance Cable length Specifications Model
3 m
M12 connector (8-pin)
F39-JD3A
7 m F39-JD7A
10 m F39-JD10A
15 m F39-JD15A
20 m F39-JD20A
Appearance Cable length Specifications Model
0.5 m
M12 connector (8-pin)
F39-JDR5B
1 m F39-JD1B
3 m F39-JD3B
5 m F39-JD5B
7 m F39-JD7B
10 m F39-JD10B
15 m F39-JD15B
20 m F39-JD20B
Appearance Cable Length Model
0.3 m F39-JJR3K
Type Appearance Cable Length Model Application
Series connection
cable
0.3 m F39-JJR3W *1
For series connection *2
When using the Water-resistant Case. *3
Side-by-side Series
connection cable
0.06 m F39-JJR06L *1
Dedicated cable to materialize series
connection with minimum length without
connector cable of the main sensor unit
0.15 m F39-JJR15L *1
Emitter
Receiver
Cable is grey
Cable is black
Double-Ended Cable
F39-JDB
Single-Ended Cable
F39-JDA
F39-JDB-L (Grey) F39-JDA-L (Grey)
F39-JDB-D (Black) F39-JDA-D (Black)
Double-Ended Cable
F39-JD@B
Series connection cable for extension
F39-JJR3W
F39-JD@B-D (Black)
F39-JD@B-L (Grey)
Cable is black
Cable is grey
Cable is black
Cable is grey
Remove the cap
Remove the cap
Emitter
Receiver
Emitter
Receiver