F3SJ-E/F3SJ-B/F3SJ-A
34
Function List
Functions that can be used on F3SJ are shown as follows: Refer to the F3SJ User's Manual for details. For manual number, check the "Related
Manuals" at the end of the catalog.
✓: Can be used.
X: Cannot be used.
Basic functions
*1. Cannot be used at muting.
*2. The muting time for the F3SJ-A can be set via the software tool. The muting time for the F3SJ-B cannot be changed.
Functions for individual applications
Wiring/mounting related function
*3. Convenient to calculate safety distance.
Indicator related functions
Note: The specifications of the models with the suffixes "-01TS", "-02TS" or "-TS" are different.
Refer to the Specifications.
*4. An external Indicator can be connected to the F3SJ-B auxiliary output .
*5. An external Indicator can be connected to the F3SJ-A auxiliary output 1 and 2, external Indicator 1 and 2 .
Function F3SJ-E (EASY) F3SJ-B (BASIC) F3SJ-A (ADVANCED)
Self-test function ✓✓✓
External test function ✓✓✓
External device monitoring function X ✓ *1 ✓
Interlock function X ✓ *1 ✓
Auxiliary output function X ✓✓
Muting function *2X✓✓
Override function X ✓✓
Partial muting function XX✓
Position detection muting function XX✓
Fixed blanking function XX✓
Floating blanking function XX✓
Warning zone function XX✓
Use of setting tools XX✓
Series connection function X ✓✓
Dead space less (single connection) ✓✓✓
Dead space less (series connection) XX✓
Response time integration (15 ms) *3 ✓✓X
Simple wiring ✓ XX
Connector cable X ✓✓
Quick mounting ✓✓X
TOP/BOTTOM indicator for beam
adjustment
✓✓X
Laser Pointer ✓✓✓
External indicator output X ✓ *4 ✓ *5
Muting error display X ✓ X