When conforming to EMC standards, refer to the information
provided in this datasheet for cable selection and other conditions.
This is a class A product. In residential areas it may cause radio
interference, in which case the user may be required to take
adequate measures to reduce interference.
Basic insulation is provided between the po
wer supply and in
put
terminals. (No insulation is provided between the power supply and
input terminals for the H5CC-A11F.) Basic insulation is provided
between power supply and output terminals, and between input
and output terminals.
When double insulation or reinforced insulation is required, apply
double insula
tion or r
einforced insulation as defined in IEC 60664
that is suitable for the maximum operating voltage with clearances
or solid insulation.
Connect the input and output terminals to devices that do not have
any expose
d char
ged parts.
Conformance to EN/IEC Standards