6 Multifunction Digital Timer H5CX-A/-L
Life-test Curve (Reference Values)
Reference: A maximum current of 0.15 A can be switched at
125 VDC (cosf=1) and a maximum current of 0.1 A
can be switched if L/R is 7 ms. In both cases, a life of
100,000 operations can be expected. The minimum
applicable load is 10 mA at 5 VDC (failure level: P).
Inrush Current (Reference Values)
1,000
500
100
50
10
0
12345
Switching operations (× 10
4
)
30 VDC L/R=7 ms
250 VAC cosφ=0.4
250 VDC/30 VDC
cosφ=1
Load current (A)
Voltage Applied voltage Inrush current
(peak value)
Time
100 to 240 VAC 264 VAC 5.3 A 0.4 ms
24 VAC/
12 to 24 VDC
26.4 VAC 6.4 A 1.4 ms
26.4 VDC 4.4 A 1.7 ms

Other manuals for Omron H5CX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron H5CX and is the answer not in the manual?

Omron H5CX Specifications

General IconGeneral
Time Range0.001 s to 9999 h
Mounting MethodFlush mounting
Output TypeRelay or Transistor
Control OutputRelay or Transistor
Operating Temperature-10 to 55°C
Storage Temperature-25 to 65°C
Input TypeNPN or PNP
Power Supply Voltage24V AC/DC, 100-240V AC
Operating Voltage Range85% to 110% of rated voltage
Operating ModesON-delay, One-shot, Interval
Contact Rating5 A at 250 VAC
MountingPanel
Dimensions48 x 48 mm
Protection StructureIP66 (front panel)