6 Multifunction Digital Timer H5CX-A/-L
Life-test Curve (Reference Values)
Reference: A maximum current of 0.15 A can be switched at
125 VDC (cosf=1) and a maximum current of 0.1 A
can be switched if L/R is 7 ms. In both cases, a life of
100,000 operations can be expected. The minimum
applicable load is 10 mA at 5 VDC (failure level: P).
Inrush Current (Reference Values)
1,000
500
100
50
10
0
12345
Switching operations (× 10
4
)
30 VDC L/R=7 ms
250 VAC cosφ=0.4
250 VDC/30 VDC
cosφ=1
Load current (A)
Voltage Applied voltage Inrush current
(peak value)
Time
100 to 240 VAC 264 VAC 5.3 A 0.4 ms
24 VAC/
12 to 24 VDC
26.4 VAC 6.4 A 1.4 ms
26.4 VDC 4.4 A 1.7 ms