Cam Positioner H8PS 9
Input Connections
Only the Encoder inputs are connected with 8-output Models. The inputs are no-voltage (short-circuit or open) inputs.
No-voltage Inputs
No-voltage Input Signal Levels
Note: Use a maximum DC power supply of 30 V.
Output Connections
Note: Internal circuit damage may result from a short circuit in the load.
NPN Output Models
Note: Do not exceed 1.6 A total for all cam outputs and the RUN
output.
PNP Output Models
Note: Do not exceed 1.6 A total for all cam outputs and the RUN
output.
H8PS-16@
H8PS-32@
6 7 8 9
10 11
Note: Operates when the contact turns ON.
COM
Bank 1
Bank 2
Bank 4
Origin
Start
Sensor, etc.
H8PS-16@
H8PS-32@
6 7 8 9
10 11
Note: Operates when the transistor turns ON.
COM
Bank 1
Bank 2
Bank 4
Origin
Start
H8PS-16@
H8PS-32@
Note: O
p
erates when the transistor turns ON.
PLC,
sensor,
etc.
6 7 8 9
10 11
COM
Bank 1
Bank 2
Bank 4
Origin
Start
Open Collector
Contact Input
Voltage-output sensors can also be connected.
Connection Examples
No-contact inputs Short-circuit level for transistor ON
Residual voltage: 2 V max.
Impedance when ON: 1 k
max.
(The leakage current is approx. 2 mA
when the impedance is 0
.)
Open level for transistor OFF
Impedance when OFF: 100 k
min.
Contact inputs Use a contact that can adequately switch
2 mA at 5 V.
Item Cam outputs,
RUN output
Pulse output
Output method NPN open collector
Dielectric strength 30 VDC
Rated current 100 mA (See note.) 30 mA
Residual voltage 2 VDC max. 0.5 VDC max.
Leakage current 100
µA max. 5 µA max.
Note: Always connect a diode to absorb
counter-electromotive force when
connecting an inductive load.
Load
Outputs
COM/()
(See note.)
Item Cam outputs,
RUN output
Pulse output
Output method PNP open collector
Dielectric strength 8-output Models: 30 VDC
16-/32-output Models: 26.4 VDC
Rated current 100 mA (See note.) 30 mA
Residual voltage 2 VDC max.
Leakage current 100
µA max.
Vs
Load
Note: Always connect a diode to absorb
counter-electromotive force when
connecting an inductive load.
Outputs
COM/()
(See note.)

Related product manuals