EasyManua.ls Logo

Omron H7BX-A - User Manual

Omron H7BX-A
170 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Multifunction Counter H7BX 1
Multifunction Counter
H7BX
DIN 72×72 mm Multifunction Counter with a Bright,
Easy-to-view, Negative Transmissive LCD.
Highly visible display with backlit transmissive LCD.
Selectable display color (red/green) enables checking output status at a
distance.
Easy operation with a key for each digit.
Perform all basic settings with a DIP switch.
Provides a total and preset counter, batch counter, dual counter, and
tachometer (See note.).
Wide range of inputs accepted for NPN/PNP inputs (multi-inputs) and 2-
wire DC sensors.
Complies with UL, CSA, and CE marking.
Degree of protection: IP54 equivalent (front section only).
Note: The functions that can be selected depend on the model.
Ordering Information
List of Models
Accessories (Order Separately)
Note: Supplied with the H7BX.
Be sure to read Safety Precautions on page 25.
External power supply Output type Supply voltage 1-stage 2-stage
12 VDC
Contact and
NPN transistor output
100 to 240 VAC H7BX-A H7BX-AW
24 VAC/12 to 24 VDC H7BX-AD1 H7BX-AWD1
Name Model
Soft Cover Y92A-72F1
Hard Cover Y92A-72
Terminal Cover (See note.) Y92A-72T
Question and Answer IconNeed help?

Do you have a question about the Omron H7BX-A and is the answer not in the manual?

Omron H7BX-A Specifications

General IconGeneral
BrandOmron
ModelH7BX-A
CategoryCash Counter
LanguageEnglish

Summary

Ordering Information

List of Models

Lists available H7HP models with their specifications.

Specifications

Ratings

Details the specifications and ratings for H8PS models.

I;O Functions

Using as a Counter

Explains input and output functions when the unit is used as a counter.

Connections

Terminal Arrangement

Shows terminal layouts for H8PS models based on output config.

Input Circuits

Illustrates the input circuit configurations for tachometers.

DIP Switch Settings

Explains DIP switch settings for H7HP operation.

Input Connections

No-voltage Inputs (NPN Inputs)

Details input connections for no-voltage NPN sensors.

Voltage Inputs (PNP Inputs)

Details input connections for voltage PNP sensors.

Output Connections

Shows output connections for NPN and PNP output models.

Nomenclature

Dimensions

Provides dimensions for tachometer models and panel cutouts.

Operating Procedures

Setting Procedure Guide

Provides a step-by-step guide for setting up the counter functions.

Flow of Operation

Outlines the sequence of operations for the Cam Positioner.

Settings for Basic Functions

Explains how to change modes and set basic functions.

Settings for Basic Operations

Setting Advanced Functions

Explanation of Functions

Advanced Functions

Details advanced tachometer functions such as prescale value and auto-zero time.

Operation in Run Mode

Input Modes and Present Value

Input;Output Mode Settings

Total and Preset Counter Operation

Batch Counter Operation

Dual Counter Operation

Settings for Advanced Functions

Output Mode Settings

Key Protect Level

Self-diagnostic Function

Safety Precautions

Operating Environment

Details environmental conditions for safe and optimal operation of the H7BX.

Installation and Wiring

Covers essential steps for safely installing and wiring the unit.

Handling

Offers important advice on handling the product to prevent damage or injury.

Precautions for Correct Use

Warranty and Application Considerations

Warranty and Limitations of Liability

Outlines OMRON's warranty terms and limitations of liability.

Safety and Reliability

Model Number Structure

Model Number Legend

Explains the model number coding for H8PS Cam Positioner.

Tachometer Function Ratings

I;O Functions for Counter Operation

Operating Procedures (Tachometer Function)

Settings for Basic Operations

Guides setting basic tachometer parameters using DIP switches.

H7 CX-A@-N Nomenclature

Counter Operating Procedures

Output Mode Setting and Operation

Precautions for the H7 CX-R

Terminal Arrangement and Wiring Connections

Setting Procedure

Safety Precautions (Common)

Operation

Operating Modes

Describes the operating modes for H7HP Total and Time Counters.

Precautions (Common)

Power Supply

Highlights precautions related to power supply voltage and connections.

High-visibility, IP66;NEMA4 Protection Total Counter;Time Counter Range

Compact Total Counters and Time Counters with Easy-to-read Displays and IP66 G;NEMA4 Water and Oil Resistance

Connections (Common)

Input Connections

Illustrates input connections for H7GP/H7HP models, covering NPN and PNP inputs.

Simple Programming

High Speed Up To 1,600 r;min

High Precision Up To 0.5° (at 720 Resolution)

Bank Function for Multi-product Production

Speed Display and Speed Alarm Output

Advance Angle Compensation Function to Compensate for Output Delays

Output Cable Connections (16-;32-output Models Only)

1. E5 ZE-CBL200 Connector-type Output Cable (Order Separately) Connections

2. Y92 S-41-200 Discrete Wire Output Cable (Order Separately) Connections

Operating Mode

Ratings and Characteristics

Safety Precautions (Encoder)

Precautions for Correct Use

Provides guidelines for the correct and safe use of encoders.

Safety Precautions (Cam Positioner)

Precautions for Safe Use

General safety precautions for using the H8PS Cam Positioner.

Setting Resolution and Rotation Direction

Setting the Origin

Setting ON;OFF Angles in Manual Mode

Setting ON;OFF Angles in Teaching Mode

Checking Timing (Test Mode)

Operation (Run Mode)

Starting Operation

Explains how to start the Cam Positioner in Run Mode.

All Protection Function

Explains how to enable/disable all key and switch protection.

Clearing Settings

Advanced Functions

Advance Angle Compensation (ADV) Function

Bank Functions (f7;f8;f9)

Self Diagnostic Function

Related product manuals