10 Cam Positioner H8PS
Operating Mode
Functions
The H8PS Cam Positioner receives angle signal inputs from the Dedicated Absolute Encoder and outputs the preset ON/OFF angles as cam outputs.
Program Examples
1. H8PS-8@ (8-output Models)
2. H8PS-16@ /-32@ (16-/32-output Models)
Note: The entire cam program can be changed at one time with 16- and 32-output Models with the bank function (banks 0 to 7).
For details on the procedure for switching banks, refer to page 28.
Cam output
(cam number)
Step 0 Step 1 Step 9
ON angle OFF angle ON angle OFF angle ON angle OFF angle
145° 90° 135° 225° 270° 315°
20° 90° 135° 180° --- ---
890° 225° 270° 285° 315° 345°
Cam output 1
Cam output 2
Cam output 8
Pulse output
(See note 1.)
RUN output
Note 1: The number of pulses per Encoder rotation
and the pulse output start angle can be set.
Note 2: With counterclockwise rotation (359°, 358°
...1°, 0°), step 0 for cam output 1 turns ON
at 89° and OFF at 44° at in the diagram.
0° 45° 90° 135° 180° 225° 270° 315° 0° 45°
Step 1 Step 9
Step 0
Step 0
Outputs a preset number of pulses per Encoder rotation. (Default setting: 60 pulses/revolution)
(ON/OFF ratio 1:1)
ON during Run or Test Mode. OFF when an error occurs.
Step 1
Step 1
Step 9
Step 0
Cam output 1
Cam output 2
Cam output 32
Pulse output
(See note 1.)
RUN output
Start input
(See note 2.)
Note 1: The number of pulses per Encoder rotation
and the pulse output start angle can be set.
Note 2: Be sure to turn ON the start input in Run and
Test modes. Otherwise, there will be no
outputs (output prohibited), including the cam
outputs, pulse output, and RUN output.
Note 3: With counterclockwise rotation (359°, 358°
...1°, 0°), step 0 for cam output 1 turns ON at
89° and OFF at 44° in the diagram.
0° 45° 90° 135° 180° 225° 270° 315° 0° 45°
Step 0
Step 0
Outputs a preset number of pulses per Encoder rotation. (Default setting: 60 pulses/revolution)
(ON/OFF ratio 1:1)
ON during Run or Test Mode. OFF when an error occurs.
Step 1
Step 1
Step 9Step 0
Step 1
Step 9
Cam Program (Bank No. 7)
Cam Program (Bank No. 2)
Cam Program (Bank No. 1)
Cam Program (Bank No. 0)
Cam output
(cam number)
Step 0 Step 1 Step 9
ON angle OFF angle ON angle OFF angle ON angle OFF angle
145° 90° 135° 225° 270° 315°
20° 90° 135° 180° --- ---
32 90° 225° 270° 285° 315° 345°