24
H7CX (Counter Function)H7CX (Counter Function)
Reset Function List
Function 1-stage/2-
stage counter
Total and preset counter Batch counter Dual counter
Screen
displayed in
run mode
Present value/
set value (1, 2)
Present value/
set value
Total count
value
Present value/
set value
Batch count
value/batch
count set
value
Dual count
value/dual
count set
value
CP1 present
value/CP2
present value
Reset/reset 1 Present value
and output re-
set.
Present value and output reset. Present value and output reset. Only the CP1 present value is re-
set.
Total reset/
reset 2
No effect. Only the total count value is re-
set.
Batch count value and batch out-
put reset.
Only the CP2 present value is re-
set.
Reset key Present value
and output re-
set.
Present value
and output re-
set.
Present value,
total count val-
ue, and output
reset.
Present value
and output re-
set.
Present value,
batch count
value, output
and batch out-
put reset.
CP1 present value, CP2 present
value, dual count value, and out-
put reset.