EasyManuals Logo

Omron H7CX Series User Manual

Omron H7CX Series
45 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #27 background imageLoading...
Page #27 background image
30
H7CX (Tachometer Function)H7CX (Tachometer Function)
Output Mode Settings
Output
mode
setting
Upper and
lower limit
(HI-LO)
Area
(AREA)
Condition OUT1 set value
OUT2 set value OUT1 set value
>
OUT2 set value
ON
condition
for OUT1
OUT1 set value
measurement value
OUT2 set value OUT2 set value
measurement value
OUT1 set value
ON
condition
for OUT2
measurement value < OUT1 set value
or
measurement value > OUT2 set value
measurement value < OUT2 set value
or
measurement value > OUT1 set value
Upper
limit
(HI-HI)
Lower
limit
(LO-LO)
OUT1
OUT2
(Lower-limit) OUT1 set value
(Upper-limit) OUT2 set value
ON condition for OUT1: measurement value
OUT1 set value
ON condition for OUT2: measurement value
OUT2 set value
Measurement value
OUT1
OUT2
OUT1 set value
OUT2 set value
Measurement value
OUT1
OUT2
(Upper-limit) OUT1 set value
(Upper-limit) OUT2 set value
ON condition for OUT1: Measurement value
OUT1 set value
ON condition for OUT2: Measurement value
OUT2 set value
Measurement value
OUT1
OUT2
(Lower-limit) OUT1 set value
(Lower-limit) OUT2 set value
ON condition for OUT1: Measurement value
OUT1 set value
ON condition for OUT2: Measurement value
OUT2 set value
Measurement value

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron H7CX Series and is the answer not in the manual?

Omron H7CX Series Specifications

General IconGeneral
Input SignalContact
Power Supply12-24 VDC or 100-240 VAC
OutputRelay
MountingPanel mount
Storage Temperature-25 to 65°C (with no icing or condensation)
Weight200 g

Related product manuals