1-24
Program Example Section 1-10
CompoWay/F
Communications
Operation Example Reading the present value of Unit No.01.
RUN
SEND DATA:010000101C00002000001
RESPONSE:010000010100000000014F
SEND DATA: [STX] 01 00 0 0101 C0 0002 00 0001 [ETX] [BCC]
Number of elements
Bit position
Read start address
Variable type
MRC/SRC
SID
Sub-address
Node No.
RESPONSE: [STX] 01 00 00 0101 0000 0000014F [ETX] [BCC]
Data to be read
Response code
MRC/SRC
End code
Sub-address
Node No.