4 Installation and Wiring
4-46
NJ-series CPU Unit Hardware User’s Manual (W500)
Additional Information
To remove the signal lines from the connector, press down on the orange tab while pulling out
the signal line, as shown in the following diagram.
Precautions for Correct UsePrecautions for Correct Use
To remove the connector from the Unit, fully unscrew the set screws from both sides of the con-
nector, and then remove the connector. Forcibly pulling the connector while the set screws are
still attached may damage the connector.