Appendices
A - 62
NX-series Position Interface Units Users Manual (W524)
The following table shows the settings for the Load Rejection Output Setting object.
This object sets the deceleration rate used when the Load Rejection Output Setting object is set to
Deceleration stop with set deceleration rate.
The deceleration rate sets the time for deceleration from the pulse output maximum velocity
(500 kpps).
This object sets the maximum number of interpolations for missing synchronization commands.
Set this object to 0 to disable the function.
Index
(hex)
Subin-
dex
(hex)
Object name Default
Data
range
Unit Data type Access
I/O
allo-
cat-
ion
Data
attri-
bute
5020 --- Load Rejection Output
Setting
No --- --- --- --- --- ---
00 Number of Entries 1 1 --- USINT RO No ---
01 Ch1 Load Rejection Out-
put Setting
0 0 or 1 --- USINT RW No Y
Set value Description
0 Immediate stop
1 Deceleration stop with set deceleration
rate
Index
(hex)
Subin-
dex
(hex)
Object name Default Data range Unit Data type Access
I/O
allo-
cat-
ion
Data
attri-
bute
5021 --- Deceleration at Load
Rejection
--- --- --- --- --- --- ---
00 Number of Entries 1 1 --- USINT RO No ---
01 Ch1 Deceleration at
Load Rejection
00 to
500,000,000
ms UDINT RW No Y
Index
(hex)
Subin-
dex
(hex)
Object name Default
Data
range
Unit Data type Access
I/O
allo-
cat-
ion
Data
attri-
bute
5022 --- Number of Synchroniza-
tion Command Interpola-
tions
--- --- --- --- --- --- ---
00 Number of Entries 1 1 --- USINT RO No ---
01 Ch1 Number of Synchro-
nization Command Inter-
polations
2 0 to 16 Interpola-
tions
UINT RW No Y