2-29
2-2-5 Peripheral Device Connection Examples
j Connecting to Peripheral Devices
R
T
U
V
W
CN2
1
3
2
4
NF
E
MCCB
PL
B
1MC
XB
E
X
M
ON
1MC X
CN1
12
to 24 VDC
35 ALMCOM
BKIR 7
OGND 10
XB
OFF
CN1
34 ALM
12 to 24 VDC
24VDC
RT
CN1
Single-phase, 200/230 VAC, 50/60 Hz (R88D-UEPH)
Single-phase,
100/1
15 VAC, 50/60 Hz (R88D-UEPL)
Noise filter
Class-3 ground
(to 100 Ω or less)
Main-circuit
power supply
Main-circuit connector
Surge killer
Servo error display
OMNUC
U-series UE model
AC Servo Driver
R88D-CAUS
(-CAUB)
Power Cable
OMNUC
U-series UE model
AC Servomotor
Class-3 ground
(to 100 Ω or less)
User’s control device
R88A-CRUC
Encoder Cable
X
X
1MC
(See note)
R88A-CPUS
General-purpose
Control Cable
Note Use an independent power supply when using an electromagnetic brake.