2-32
2-3-2 Wiring Servo Drivers
Provide proper wire diameters, ground systems, and noise resistance when wiring terminal blocks.
j Wiring Terminal Blocks
24 VDC
Red
White
Blue
Green
Black
Black
To Motor
Power Cable
R88A-CAU001
R88A-CAU01B (with brake)
(The broken lines indicate signal
lines for the brake. There is no
polarity on these lines.)
Power supply input terminals
Main-circuit DC output terminals
Terminal
label
Name Function
L1
Power supply
input
The commercial power supply input terminals for the main circuit and the
control circuitry.
L2
R88D-UEPV: Single-phase 200/230 VAC (170 to 253 V) 50/60 Hz
R88D-UEPW: Single-phase 100/115 VAC (85 to 127 V) 50/60 Hz
+
Main circuit DC
p
When there is a high level of regenerative energy in a multi-axis system, the
+ terminals can be connected together and the terminals can be connected
–
output + term
na
s can
e connecte
toget
er an
t
e – term
na
s can
e connecte
together to increase the ability to absorb regenerative energy
U
Motor connection
Red
These are the output terminals to the Servomotor. Be careful to wire
V
terminals
White
them correctly.
W Blue
Frame ground Green Ground to a class-3 ground (to 100 Ω or less) or better.
Note Refer
to
3-8
Regenerative Energy Absorption
for the methods to calculate regenerative energy
.
System Design and Installation
Chapter
2