<Installing the BU3002SWG vertically>
●
Stabilize the casters
●
How to stabilize the xed stand
Use a monkey wrench or spanner to loosen the xed
stand nuts.
Unscrew the feet of the xed stand until they reach
the oor.
Continue to unscrew the feet of the xed stand until
the casters no longer touch the oor.
Once the xed stand feet are rmly on the oor, turn
the nuts counter-clockwise to tighten them and lock
the feet in place.
* The feet can be anchored to the oor with screws if you use BUP300SG mounting brackets (sold
separately).
Refer to the BUP300SG instruction manual for more details.
<Installing the BU3002SWG horizontally>
●
How to remove the bottom casters
Install the BU3002SWG so that the control panel is facing upward.
Loosen the screws in the 6 locations shown in the diagram below.
Remove caster mounting plate.
Casters locked
Casters unlocked
* BUP300SG mounting brackets (sold separately) can be used for easy mounting on an EIA/JIS 19-
inch rack.
Refer to the BUP300SG instruction manual for more details.