12
2. Installation and Connection
<Installing the BU3002SWG vertically>
Stabilize the casters
How to stabilize the xed stand
Use a monkey wrench or spanner to loosen the xed
stand nuts.
Unscrew the feet of the xed stand until they reach
the oor.
Continue to unscrew the feet of the xed stand until
the casters no longer touch the oor.
Once the xed stand feet are rmly on the oor, turn
the nuts counter-clockwise to tighten them and lock
the feet in place.
* The feet can be anchored to the oor with screws if you use BUP300SG mounting brackets (sold
separately).
Refer to the BUP300SG instruction manual for more details.
<Installing the BU3002SWG horizontally>
How to remove the bottom casters
Install the BU3002SWG so that the control panel is facing upward.
Loosen the screws in the 6 locations shown in the diagram below.
Remove caster mounting plate.
Casters locked
Casters unlocked
* BUP300SG mounting brackets (sold separately) can be used for easy mounting on an EIA/JIS 19-
inch rack.
Refer to the BUP300SG instruction manual for more details.