This manual gives you important information to use the this unit safely and therefore be sure to
read it before installation and use.
Keep this manual handy at the place where you install the this unit so that you can read it
whenever necessary.
Uninterruptible Power Supply (UPS)
Instruction Manual
BY50FW/BY75SW

Table of Contents

Questions and Answers

Omron POWLI BY50FW Specifications

General IconGeneral
Rated Capacity500VA / 300W
Output Voltage230 VAC
Output WaveformSimulated Sine Wave
Surge ProtectionYes
Communication InterfaceUSB
Warranty2 years
ModelBY50FW
Input Frequency50/60Hz
Output Frequency50/60 Hz
Battery TypeSealed Lead Acid Battery
Typical Backup Time (Full Load)3 minutes
Outlets3

Summary

OMRON UPS Safety Instructions Overview

OMRON UPS General Safety Precautions

Critical UPS Safety Warnings

Highlights critical safety warnings, including misuse causing injury, property damage, and suffocation risks.

UPS Installation and Connection Safety

Provides precautions for safe installation and connection, covering weight, grounding, and input voltage.

Safe UPS Installation and Electrical Practices

UPS Usage, Handling, and Battery Safety

UPS Operation and Battery Care Safety

Details safety measures during operation, including water hazards and battery replacement timing.

UPS Safety: Abnormal Conditions and Battery Notes

Handling UPS Abnormal Conditions

Provides guidance for responding to unusual sounds, smells, or fluid leaks from the UPS unit.

UPS Battery Replacement Safety Precautions

Details safety precautions for handling and disposing of batteries, including avoiding impact and short circuits.

OMRON UPS Installation and Connection Guide

Critical UPS Installation Safety Precautions

Provides critical safety warnings and precautions to follow before and during UPS installation and connection.

UPS Electrical Connection and Grounding Safety

Details safe practices for connecting the UPS to power outlets, including grounding and voltage requirements.

Safe UPS Installation and Environmental Practices

Verifying UPS Installation and Operation

Initial UPS Power-On and Self-Diagnostic Test

Details the steps for turning on the UPS power switch and observing the initial self-diagnostic test.

Checking UPS Status Indicators and Beeps

Explains how to check the LED display and beep status to confirm normal UPS operation after connection.

UPS Battery Mode Operation Verification

Monitoring UPS in Battery Mode

Guides on checking LED displays and beeps during Battery Mode to confirm proper power failure response.

Confirming Normal Operation Post-Battery Mode

Explains how to reconnect AC power and verify normal operation after a simulated power failure.

OMRON UPS Operational Safety Precautions

Critical Safety During UPS Operation

Covers essential safety precautions during UPS operation, including avoiding water and handling battery issues.

Responding to UPS Abnormal Conditions

Provides guidance on immediate actions if abnormal sounds, smells, or leaks are detected during UPS operation.

Basic OMRON UPS Operation and Controls

Starting and Stopping the UPS Unit

Details the procedures for starting up the UPS, including power switch operation and status indicators.

UPS Power Failure and Recovery Operations

UPS Behavior During Power Failure

Describes how the UPS switches to Battery Mode during a power failure and alerts the user with beeps.

Stopping and Restarting the UPS Unit

Explains how to stop the UPS by turning off the power switch and how it automatically recharges.

Understanding UPS Status Indicators and Beeps

UPS Normal Operation Displays and Beeps

Explains status indicators, beeps, and outputs during normal UPS operation, including stopped and ON states.

UPS Displays During Tests and Power Failures

Details status indicators and beeps during self-diagnostic tests, auto battery tests, and power failures.

UPS Failure and Overload Indicators

Interpreting UPS Error Displays and Beeps

Explains status indicators and beeps for equipment failures, such as overload and output voltage errors.

Troubleshooting UPS Overload Conditions

Details how to interpret and resolve issues related to excess connection capacity or overload conditions.

OMRON UPS Advanced Functions and Testing

Performing UPS Self-Diagnostic Tests

Details the procedure for manually performing self-diagnostic tests to check unit health and battery status.

Understanding the UPS Auto Battery Test

Explains the automatic battery test function that checks battery health and internal circuits periodically.

Configuring UPS Settings via Switches

Setting UPS Power Output Stop Delay

Explains how to configure the delay time for power output stoppage using setting switch 1.

Configuring UPS Auto Restart Settings

Details how to set the UPS to automatically restart or disable automatic restart after power restoration.

Customizing UPS Output Stop Timing

Configuring UPS Stop Signals and Communication

OMRON UPS Operation Mode Configuration

Detailed UPS Operation Mode Settings

UPS Operation Mode Selection Flow

OMRON UPS Maintenance and Battery Checks

Safety During UPS Maintenance

Provides critical safety precautions to follow when performing maintenance on the UPS unit.

OMRON UPS Battery Replacement Guide

Safety During UPS Battery Replacement

Highlights safety precautions for replacing the battery, including UL standards and potential hazards.

UPS Battery Replacement Safety Warnings

Details specific warnings for battery replacement, such as avoiding flammable gas, fluid leaks, and short circuits.

Safe UPS Battery Replacement Procedures

Precautions for UPS Battery Handling

Lists essential precautions for battery replacement, including removing jewelry and using insulated tools.

Replacing the Battery in BY50 FW UPS

Removing the Old BY50 FW Battery

Step-by-step instructions for removing the old battery from the BY50FW UPS, emphasizing safe handling.

Installing the New BY50 FW Battery

Guides on inserting the new battery, reconnecting connectors, and securing the front panel.

UPS Battery Replacement Procedures

BY50 FW UPS Battery Replacement Steps

Detailed steps for replacing the battery in the BY50FW UPS, including opening the front panel and disconnecting connectors.

BY75 SW UPS Battery Replacement Preparation

Outlines the preparation steps for replacing the battery in the BY75SW UPS, including purchasing the correct battery pack.

Completing BY50 FW Battery Replacement

Securing New Battery and Cover (BY50 FW)

Instructions on fitting the metal cover, connecting battery connectors, and securing the front panel for BY50FW.

Finalizing UPS Battery Replacement and Cleaning

BY75 SW UPS Battery Replacement Steps

Detailed steps for replacing the battery in the BY75SW UPS, including opening the front panel and removing covers.

OMRON UPS Monitoring Software Options

Understanding UPS Monitoring Software Functions

Using OMRON PowerAct Pro Software

PowerAct Pro UPS Software Operations

Using UPS Power Manager for Mac

Windows UPS Service for Auto-Save Functions

Windows Standard UPS Service Configuration

Setting Up Windows UPS Service for Shutdown

Finalizing Windows UPS Service Configuration

Configuring Windows NT UPS Service

Starting and Managing Windows UPS Service

Using OMRON UPS Contact Signals

UPS Remote Control and Contact Signal Connector

Implementing UPS Contact Signal Circuits

Measuring and Estimating UPS Backup Time

Method for Measuring UPS Backup Time

Provides step-by-step instructions for measuring the UPS backup time under various operating systems.

Calculating Estimated UPS Backup Time

Explains how to estimate backup time by converting connected device capacity (VA, A) to Watts.

UPS Backup Time Estimation Graph

Interpreting UPS Backup Time Graph

Shows a graph relating connection capacity (Watt) to backup time (minutes) for BY50FW and BY75SW.

Troubleshooting OMRON UPS Issues

Troubleshooting UPS Power Issues

Addresses problems like the UPS not operating, LED display issues, and insufficient charging.

Troubleshooting UPS Battery and Overload Faults

Details how to diagnose and resolve battery replacement alerts, overload conditions, and continuous beeping.

OMRON UPS Technical Specifications