12.4 d: REFERENCE
592 SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
Note:
The upper limit value changes when the E1-04 [Max Output Frequency] and d2-01 [FRef Upper Limit] values change.
When A1-02 = 6, 7 [Control Method = PM AOLVector, PM CLVector], the drive changes o1-03 = 1 [0.01% (100%=E1-04)].
This parameter sets the frequency reference of Multi-Step Speed 7.
d1-08 Reference 8
No.
(Hex.)
Name Description
Default
(Range)
d1-08
(0287)
RUN
Reference 8
Sets the frequency reference in the units from o1-03 [FrqDisplay Unit Selection].
0.00 Hz
(0.00 - 590.00 Hz)
Note:
The upper limit value changes when the E1-04 [Max Output Frequency] and d2-01 [FRef Upper Limit] values change.
When A1-02 = 6, 7 [Control Method = PM AOLVector, PM CLVector], the drive changes o1-03 = 1 [0.01% (100%=E1-04)].
This parameter sets the frequency reference of Multi-Step Speed 8.
d1-09 Reference 9
No.
(Hex.)
Name Description
Default
(Range)
d1-09
(0288)
RUN
Reference 9
Sets the frequency reference in the units from o1-03 [FrqDisplay Unit Selection].
0.00 Hz
(0.00 - 590.00 Hz)
Note:
The upper limit value changes when the E1-04 [Max Output Frequency] and d2-01 [FRef Upper Limit] values change.
When A1-02 = 6, 7 [Control Method = PM AOLVector, PM CLVector], the drive changes o1-03 = 1 [0.01% (100%=E1-04)].
This parameter sets the frequency reference of Multi-Step Speed 9.
d1-10 Reference 10
No.
(Hex.)
Name Description
Default
(Range)
d1-10
(028B)
RUN
Reference 10
Sets the frequency reference in the units from o1-03 [FrqDisplay Unit Selection].
0.00 Hz
(0.00 - 590.00 Hz)
Note:
The upper limit value changes when the E1-04 [Max Output Frequency] and d2-01 [FRef Upper Limit] values change.
When A1-02 = 6, 7 [Control Method = PM AOLVector, PM CLVector], the drive changes o1-03 = 1 [0.01% (100%=E1-04)].
This parameter sets the frequency reference of Multi-Step Speed 10.
d1-11 Reference 11
No.
(Hex.)
Name Description
Default
(Range)
d1-11
(028C)
RUN
Reference 11
Sets the frequency reference in the units from o1-03 [FrqDisplay Unit Selection].
0.00 Hz
(0.00 - 590.00 Hz)
Note:
The upper limit value changes when the E1-04 [Max Output Frequency] and d2-01 [FRef Upper Limit] values change.
When A1-02 = 6, 7 [Control Method = PM AOLVector, PM CLVector], the drive changes o1-03 = 1 [0.01% (100%=E1-04)].
This parameter sets the frequency reference of Multi-Step Speed 11.
d1-12 Reference 12
No.
(Hex.)
Name Description
Default
(Range)
d1-12
(028D)
RUN
Reference 12
Sets the frequency reference in the units from o1-03 [FrqDisplay Unit Selection].
0.00 Hz
(0.00 - 590.00 Hz)
Note:
The upper limit value changes when the E1-04 [Max Output Frequency] and d2-01 [FRef Upper Limit] values change.
When A1-02 = 6, 7 [Control Method = PM AOLVector, PM CLVector], the drive changes o1-03 = 1 [0.01% (100%=E1-04)].
This parameter sets the frequency reference of Multi-Step Speed 12.

Table of Contents

Other manuals for Omron Q2A-A4018-AAA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron Q2A-A4018-AAA and is the answer not in the manual?

Omron Q2A-A4018-AAA Specifications

General IconGeneral
BrandOmron
ModelQ2A-A4018-AAA
CategoryController
LanguageEnglish

Related product manuals