12.7 H: TERMINALS
670 SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
1: Forward Run
Setting Function Description
1 Forward Run
Sets the Forward Run command for 2-wire sequence 1. Set this function and H1-xx = 2 [Reverse Run] together.
ON : Forward Run
OFF : Run Stop
Note:
Turning ON the Forward Run command terminal and the Reverse Run command terminal will cause alarm EF [FWD/REV Run
Command Input Error] and the motor will ramp to stop.
Initialize the drive with a 2-wire sequence to set the Forward Run command to terminal DI1.
This function will not operate at the same time as H1-xx = 3, 4 [Run Command, FWD/REV Cmd].
Figure 12.72 2-Wire Sequence Wiring Example
2: Reverse Run
Setting Function Description
2 Reverse Run
Sets the Reverse Run command for 2-wire sequence 1. Set this function and H1-xx = 1 [Forward Run] together.
ON : Reverse Run
OFF : Run Stop
Note:
Turning ON the Forward Run command terminal and the Reverse Run command terminal will cause alarm EF [FWD/REV Run
Command Input Error] and the motor will ramp to stop.
Initialize the drive with a 2-wire sequence to set the Reverse Run command to terminal DI2.
This function will not operate at the same time as H1-xx = 3, 4 [Run Command, FWD/REV Cmd].
3: Run Command
Setting Function Description
3 Run Command
Sets the Run command for 2-wire sequence 2. Set this function and H1-xx = 4 [FWD/REV Cmd] together.
ON : Run
OFF : Stop
Note:
This function will not operate at the same time as H1-xx = 1, 2 [Forward Run, Reverse Run].
4: FWD/REV Cmd
Setting Function Description
4 FWD/REV Cmd
Sets the direction of motor rotation for 2-wire sequence 2. Set this function and H1-xx = 3 [Run Command] together.
ON : Reverse
OFF : Forward
Note:
You must input the Run command to rotate the motor.
This function will not operate at the same time as H1-xx = 1, 2 [Forward Run, Reverse Run].

Table of Contents

Other manuals for Omron Q2A-A4018-AAA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron Q2A-A4018-AAA and is the answer not in the manual?

Omron Q2A-A4018-AAA Specifications

General IconGeneral
BrandOmron
ModelQ2A-A4018-AAA
CategoryController
LanguageEnglish

Related product manuals