EasyManuals Logo

Omron Q2A-A4018-AAA Technical Manual

Omron Q2A-A4018-AAA
844 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #679 background imageLoading...
Page #679 background image
Parameter Details
12
12.7 H: TERMINALS
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual 679
Figure 12.79 Fast Stop Time Chart
3E: SCBraking NO
Setting Function Description
3E SCBraking NO
Sets operation of Short Circuit Braking (N.O.).
If a three-phase PM motor short circuits, the drive will generate braking torque in the spinning motor. This will
stop motor rotation and also prevent external forces from spinning the motor.
Note:
When A1-02 = 8 [Control Method = EZ Vector], this function is available if you use a PM motor.
Refer to b2: DC INJ / SHORT CKT BRAKE for more information.
ON : Short Circuit Braking is enabled.
OFF : Normal operation
3F: SCBraking NC
Setting Function Description
3F SCBraking NC
Sets operation of Short Circuit Braking (N.C.).
If a three-phase PM motor short circuits, the drive will generate braking torque in the spinning motor. This will
stop motor rotation and also prevent external forces from spinning the motor.
Note:
When A1-02 = 8 [Control Method = EZ Vector], this function is available if you use a PM motor.
Refer to b2: DC INJ / SHORT CKT BRAKE for more information.
ON : Normal operation
OFF : Short Circuit Braking is enabled.
40: KEB Thru1 NC
Setting Function Description
40 KEB Thru1 NC
Sets operation of the KEB1 function through the KEB Ride-Thru 1 (N.C.).
ON : Normal operation
OFF : Deceleration during momentary power loss
When you enable KEB Ride-Thru 1, set L2-29 [KEB Method]. The drive operates with the selected KEB method.
Note:
If you set KEB Ride-Thru 1 [H1-xx = 40, 41] and KEB Ride-Thru 2 [H1-xx = 42, 43] at the same time, the drive will detect oPE03
[Multi-Function Input Setting Err].
Refer to KEB Ride-Thru function for more information.
41: KEB Thru1 NO
Setting Function Description
41 KEB Thru1 NO
Sets operation of the KEB1 function through the KEB Ride-Thru 1 (N.O.).

Table of Contents

Other manuals for Omron Q2A-A4018-AAA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron Q2A-A4018-AAA and is the answer not in the manual?

Omron Q2A-A4018-AAA Specifications

General IconGeneral
BrandOmron
ModelQ2A-A4018-AAA
CategoryController
LanguageEnglish

Related product manuals