Parameter Details
12
12.7 H: TERMINALS
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual 735
■ H7-13 Virtual Out2 Delay Time
No.
(Hex.)
Name Description
Default
(Range)
H7-13
(11A7)
Expert
Virtual Out2 Delay Time
Sets the minimum ON time for virtual digital output 2.
0.1 s
(0.0 - 25.0 s)
■ H7-14 Virtual Out3 Select Function
No.
(Hex.)
Name Description
Default
(Range)
H7-14
(11A8)
Expert
Virtual Out3 Select
Function
Sets the function for virtual digital output 3.
0
(0 - 1A7)
■ H7-15 Virtual Out3 Delay Time
No.
(Hex.)
Name Description
Default
(Range)
H7-15
(11A9)
Expert
Virtual Out3 Delay Time
Sets the minimum ON time for virtual digital output 3.
0.1 s
(0.0 - 25.0 s)
■ H7-16 Virtual Out4 Select Function
No.
(Hex.)
Name Description
Default
(Range)
H7-16
(11AA)
Expert
Virtual Out4 Select
Function
Sets the function for virtual digital output 4.
0
(0 - 1A7)
■ H7-17 Virtual Out4 Delay Time
No.
(Hex.)
Name Description
Default
(Range)
H7-17
(11AB)
Expert
Virtual Out4 Delay Time
Sets the minimum ON time for virtual digital output 4.
0.1 s
(0.0 - 25.0 s)
■ H7-30 Virtual AIn Select Function
No.
(Hex.)
Name Description
Default
(Range)
H7-30
(1177)
Virtual AIn Select Function
Sets the virtual analog input function.
0
(0 - 32)
■ H7-31 Virtual AIn Gain
No.
(Hex.)
Name Description
Default
(Range)
H7-31
(1178)
RUN
Expert
Virtual AIn Gain
Sets the virtual analog input gain.
100.0%
(-999.9 - 999.9%)
■ H7-32 Virtual AIn Bias
No.
(Hex.)
Name Description
Default
(Range)
H7-32
(1179)
RUN
Expert
Virtual AIn Bias
Sets the virtual analog input bias.
0.0%
(-999.9 - 999.9%)