A - 103
Appendices
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User’s Manual (I586)
A-4 Sysmac Error Status Codes
A
A-4-1 Error List
084B0000 Encoder Communi-
cations Error
Illegal data was received
from the encoder the speci-
fied number of times.
• Noise into the encoder
cable
• Contact failure of the signal
line, and disconnection of
the encoder
• Power supply undervoltage
to the encoder
√ P. A-12 9
084D0000 Non-volatile Memory
Hardware Error
An error occurred on the
non-volatile memory.
• False detection due to a
data read error that was
caused by excessive noise
• Non-volatile memory failure
√ P. A-13 0
18230000 Absolute Encoder
Multi-rotation
Counter Error
The encoder detected a
multi-rotation counter error.
• A temporary error occurred
in the encoder multi-rotation
detection function due to
vibration, impact, or con-
densation
• Encoder failure
√ P. A-13 0
18380000 System Error A hardware error due to the
self-diagnosis and a fatal
software error were
detected.
• False detection due to a
data read error that was
caused by excessive noise
• A fatal software error was
detected
• Hardware failure
√ P. A-13 1
183A0000 Non-volatile Memory
Data Error
An error of data saved in the
non-volatile memory was
detected.
• Power interruption or noise
occurred while parameters
other than the safety were
saved
• Power interruption or noise
occurred while the motor
identity information was
saved
• Power interruption or noise
occurred while safety
parameters were saved
√ P. A-13 1
246D0000 Motor
Non-conformity
The Servo Drive and motor
combination is not correct.
• The Servo Drive and motor
combination is not correct
√ P. A-13 2
28080000 Main Circuit Power
Supply Phase Loss
Error
The phase loss of the main
circuit power supply was
detected
• Incorrect wiring, for exam-
ple the single-phase power
supply is input to a 3-phase
input type Servo Drive
• In the case where the sin-
gle-phase power supply is
input to a single- and
3-phase input type Servo
Drive, the phase loss detec-
tion is enabled.
• The power supply voltage is
low or insufficient
• Broken wiring of the main
circuit power supply input
• Servo Drive failure
√ P. A-13 3
Event code
(hex)
Event name Description Assumed cause
Level
Refer-
ence
Min
Obs
Info

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron R88D-1SN10F-ECT and is the answer not in the manual?

Omron R88D-1SN10F-ECT Specifications

General IconGeneral
BrandOmron
ModelR88D-1SN10F-ECT
CategoryController
LanguageEnglish

Related product manuals