EasyManuals Logo

Omron R88D-1SN10F-ECT User Manual

Omron R88D-1SN10F-ECT
974 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #906 background imageLoading...
Page #906 background image
Appendices
A - 120
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User’s Manual (I586)
Event name Fan Error Event code 083D0000 hex
Description The rotation speed of the fan is 40% or less of the rating and the cooling performance decreases.
Source
EtherCAT Master Function Mod-
ule
Source details
Slave
Detection
timing
Continuously
Error
attributes
Level
Minor fault
Recovery
Error reset
(after resetting
slave errors)
Log category
System log
Effects User program Continues. Operation Power drive circuit is OFF
Indicators
EtherCAT NET RUN EtherCAT NET ERR EtherCAT LINK/ACT
--- --- ---
System
-defined
variables
Variable Data type Name
None None None
Cause and
correction
Assumed cause Correction Prevention
There is a foreign matter in the
cooling fan and it blocks the rota-
tion
Check whether there is a foreign
matter in the fan. If you find a for-
eign matter, remove it.
Do not use the fan in an area sur-
rounded by excessive foreign mat-
ter. Also, do not allow foreign
objects to enter.
Cooling fan failure If there is no improvement after
you performed the correction
above, replace the Servo Drive.
Attached
information
None
Precautions/
Remarks
AL status code: -, Error No.: 5900 hex