A - 59
 Appendices
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User’s Manual (I586)
A-2  CoE Objects
A
A-2-8  Servo Drive Profile Object
 
 
• This object gives the supported homing methods.
 
 
• This object gives the amount of following error.
 
 
 
• This object gives the velocity command value which is generated in the position control of the Servo 
Drive.
• The displayed value may have an error due to the unit conversion from [r/min] to [command unit/s].
 
 
 
• This object gives the command position which is generated in the Servo Drive.
 
 
 
• This object gives each function I/O status of the Servo Drive.
Index 
(hex)
Sub-
index 
(hex)
Object name
Setting 
range
Unit
Default 
setting
Data 
attri-
bute
Size Access
PDO 
map
Com-
plete 
access
Modes of 
operation
60E3 --- Supported hom-
ing methods
--- --- --- --- --- --- --- Possible ---
00 Number of 
entries
--- --- 07 hex --- 1 byte 
(U8)
RO --- --- ---
01 1st supported 
homing method
--- --- 8 --- 2 bytes 
(INT16)
RO --- --- hm
02 2nd supported 
homing method
--- --- 12 --- 2 bytes 
(INT16)
RO --- --- hm
03 3rd supported 
homing method
--- --- 19 --- 2 bytes 
(INT16)
RO --- --- hm
04 4th supported 
homing method
--- --- 20 --- 2 bytes 
(INT16)
RO --- --- hm
05 5th supported 
homing method
--- --- 33 --- 2 bytes 
(INT16)
RO --- --- hm
06 6th supported 
homing method
--- --- 34 --- 2 bytes 
(INT16)
RO --- --- hm
07 7th supported 
homing method
--- --- 37 --- 2 bytes 
(INT16)
RO --- --- hm
Index 
(hex)
Sub-
index 
(hex)
Object name
Setting 
range
Unit
Default 
setting
Data 
attri-
bute
Size Access
PDO 
map
Com-
plete 
access
Modes of 
operation
60F4 --- Following error 
actual value
--- Com-
mand 
unit
--- --- 4 bytes 
(INT16)
RO TxPDO Not possi-
ble
csp, pp, 
hm
Index 
(hex)
Sub-
index 
(hex)
Object name
Setting 
range
Unit
Default 
setting
Data 
attri-
bute
Size Access
PDO 
map
Com-
plete 
access
Modes of 
operation
60FA --- Control effort --- Com-
mand 
unit/s
--- --- 4 bytes 
(INT32)
RO TxPDO Not possi-
ble
csp, pp, 
hm
Index 
(hex)
Sub-
index 
(hex)
Object name
Setting 
range
Unit
Default 
setting
Data 
attri-
bute
Size Access
PDO 
map
Com-
plete 
access
Modes of 
operation
60FC --- Position 
demand internal 
value
--- Encoder 
unit
--- --- 4 bytes 
(INT32)
RO TxPDO Not possi-
ble
csp, pp, 
hm
Index 
(hex)
Sub-
index 
(hex)
Object name
Setting 
range
Unit
Default 
setting
Data 
attri-
bute
Size Access
PDO 
map
Com-
plete 
access
Modes of 
operation
60FD --- Digital inputs --- --- --- --- 4 bytes 
(U32)
RO TxPDO Not possi-