12 Troubleshooting and Maintenance
12 - 36
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
The lifetimes for the different drive parts are given below.
When using the Servo Drive in continuous operation, use fans or air conditioners to maintain the
ambient temperature below 40°C.
We recommend that the ambient temperature and the power supply ON time be reduced as much as
possible to lengthen the service life of the Servo Drive.
The limit of aluminum electrolytic capacitors is greatly affected by the operating ambient temperature.
Generally, an increase of 10°C in the operating ambient temperature will reduce capacitor service life
by 50%.
For example, when the operating ambient temperature is 25°C, the life expectancy will be as follows:
The aluminum electrolytic capacitors deteriorate even when the Servo Drive is stored with no power
supplied. If the Servo Drive is not used for a long time, we recommend periodic inspection and a part
replacement period of 5 years.
If the motor or Servo Drive is not to be used for a long time, or if they are to be used under conditions
worse than those described above, a periodic inspection period of 5 years is recommended.
Upon request, OMRON will inspect the Servo Drive and motor and determine if part replacement is
required.
12-5-2 Servo Drive Life Expectancy
Servo Drive Life Expectancy
Aluminum electrolytic capacitors: 28,000 hours
(at an ambient drive operating temperature of 55ºC, constant output at rated force, constant output at rated
speed, and installation as described in this manual)
Axial-flow fan: 10,000 to 30,000 hours
(The limit depends on the operating conditions.)
Inrush current prevention relay: Approx. 20,000 operations
(The limit depends on the operating conditions.)
= Life expectancy at 55°C × 2Life expectancy at 25°C
= 224,000 hours
55 - 25
10