12-3
12-1 Troubleshooting
OMNUC G5-series AC Servomotors and Servo Drives User’s Manual (with Built-in EtherCAT Communications)
  12
Troubleshooting and Maintenance
Replacing the Servo Drive
1.  Take a record of all object settings. 
Use the CX-Drive or other software and take a record of the settings of all objects. 
2.  Replace the Servo Drive.
3.  Set the objects. 
Use the CX-Drive or other software and set all of the objects. 
4.  Set up the absolute encoder.
 If a motor with an absolute encoder is used, the absolute value data in the absolute encoder is
cleared when the Servo Drive is replaced, so setup is again required. The multi-rotation data will
be different from before it was replaced, so initialize the Motion Control Unit settings.
 For details, refer to  Absolute Encoder Setup on page 10-6.