640
3Z4L Laser Micrometer Protocol Appendix N
Note 1. *Normal responses will be returned for these sequences for 5000-series and 6000-series Laser Mi-
crometers, but no processing will be performed.
2. *This sequence will be processed the same as sequence No. 425 AVG move (H) times set for 5000-
series Laser Micrometers.
3. *Memory switch settings will be ignored for these sequences for 5000-series and 6000-series Laser
Micrometers.
4. *This sequence will be processed the same as sequence No. 411 Zero run measurement start for
5000-series Laser Micrometers.
416 (01A0) Statistic processing execution (3000-series) Yes Yes
417 (01A1) Statistic processing non-execution (3000-series) Yes Yes
418 (01A2) All statistic memory clear (3000-series) Yes Yes
419 (01A3) Statistic memory clear (3000-series) Yes Yes
420 (01A4) Statistic result request (3000-series) No No
421 (01A5) Memory switch set 1 (3000-series)
No
*1
No
*1
422 (01A6) Memory switch set 2 (3000-series)
No
*1
No
*1
423 (01A7) Simple AVG times set (3000-series) Yes Yes
424 (01A8) AVG move interval set (3000-series) Yes Yes
425 (01A9) AVG move (H) times set (3000-series) Yes Yes
426 (01AA) AVG move (L) times set (3000-series)
Ye s *
2
No
427 (01AB) Automatic detection set (3000-series) No No
428 (01AC) Automatic detection release (3000-series) Yes Yes
429 (01AD) Automatic detection list request (3000-series) Yes Yes
430 (01AE) 3Z4L initialize (3000-series)
Ye s
*3
Ye s
*3
431 (01AF) Measurement condition set (4000-series) No No
432 (01B0) Measurement condition release (4000-series) No No
433 (01B1) Measurement condition list request (4000-series) No No
434 (01B2) Single run measurement start (4000-series) Yes No
435 (01B3) Deflection measurement start (4000-series)
Ye s
*4
No
436 (01B4) Continuous measurement start (scan) (4000-series) Yes No
437 (01B5) Continuous measurement start (interrupt) (4000-series) Yes No
438 (01B6) Measurement termination (4000-series) Yes No
439 (01B7) Data request (4000-series) Yes No
440 (01B8) Forced positive zero (4000-series) Yes Yes
441 (01B9) Forced negative zero (4000-series) Yes Yes
442 (01BA) Forced zero release (4000-series) Yes Yes
443 (01BB) 3Z4L initialize (4000-series)
Ye s
*3
Ye s
*3
444 (01BC) General-purpose command 1 Yes Yes
445 (01BD) General-purpose command 2 Yes Yes
446 (01BE) High calibration set No No
447 (01BF) Low calibration set No No
Sequence
No.
Communications sequence name Operation
5000 Series
6000 Series

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSMAC CJ1W-SCU21-V1 and is the answer not in the manual?

Omron SYSMAC CJ1W-SCU21-V1 Specifications

General IconGeneral
BrandOmron
ModelSYSMAC CJ1W-SCU21-V1
CategoryNetwork Hardware
LanguageEnglish

Related product manuals