PREPARATION
Fill
the
oil
cup on
the
side
of
the
distributor.
Place
a
drop
of
oil
on
each
of
the
governor
to
carburetor
link
ball
joints.
It
is
unnecessary
to
lubricate
the
generator
bearing
and
water
pump
until
time
to
do
so
as
noted
under
PERIODIC
SERVICE.
FUEL,
GASOLINE.-
Use
only
a good
grade,
clean,
fresh,
regular
automotive
type
gasoline
of
68
to
74
octane
rating.
Do
not
use
any
highly
leaded
premium
type
of
gasoline.
The
'use
of
any
gasoline
which
has
a
high
lead
content
will
necessitate
more
frequent
carbon
removal,
spark
plug,
.and
valve
servicing.
However, do
not
use
a
low
octane
gasoline,
such
as
"stove"
gas,
as
its
use
will
cause
excessive
detonation
or
"spark
knock",
and
damage
to
engine
bearings,
valves,
rings,
etc.
If
the
plant
has
the
mounted
fuel
tank,
do
not
fill
the
tank
entirely
full
of
cold
gasoline,
as
the
fuel
may
expand
as
the
plant
wanns
up,
causing
the
gasoline
to
overflow.
Observe
the
usual
precautions
when
handling
gasoline.
Do
not
fill
the
tank
when
the
plant
is
running.
On
plants
equipped
with
the
mounted
fuel
tank,
note
that
the
electric
fuel
gauge on
the
control
panel
registers
the
amount
of
fuel
in
the
tank
only
when
the
plant
is
running.
If
it
is
desired
to
check
the
fuel
when
the
plant
is
stopped,
throw
the
ignition
switch
to
the
HAND
START
position
while
making
the
observation.
Be
sure
to
return
the
switch
to
the
ELECT.
START
position.
If·
an
auxiliary
fuel
tank.
is
used,
connection
may
be
made
to
the
two
way
fuel
shut-off
valve
at
the
bottom
of
the
tank
mounted
on
the
plant.
FUEL,
NATURAL
GAS
OR
LPG.-
Make
sure
that
fuel
I!IUpply
lines
(and
tanks,
if
used)
have
been
properly
installed
and
connected.
RADIATOR.-
The
capacity
of
the
cooling
system
is
approximately
11
quarts
(U.
S.
Measure).
See
that
the
radiator
and
cylinder
block
drain
cocks
are
closed.
Fill
the
radiator
with
clean,
alkali-free
water
such
as
clean
rainwater.
The
use
of
a
rust
and
scale
inhibitor
is
recommended.
If
the
plant
will
be
exposed
to
freezing
temperatures,
use
a
standard
anti-freeze
in
the
proper
proportion.
To
avoid
loss
of
anti-freeze
through
the
overflow
pipe
due
to
expansion,
fill
only
to
approximately
2
inches
below
the
bottom
of
the
filler
neCk. Check
the
cooling
system
to
see
that
there
are
no
leaks.
If
the
foregoing
instructions
have
been
carefully
complied
with,
the
plant
should
be
ready
for
operation.
However,
before
starting
the
.plant,
carefully
study
the
paragraphs
under
the
headings
OPERATION
and
ABNORMJL
OPERATING
CONDITION
immediately
following.
8