PERIODIC SERVICE
GENERAL.-
Follow a
definite
schedule
of
inspection
and serviCing
to
assure
better
performance and
longer
life
of
the
plant
at
minimum
ex-
pense.
Service
periods
outlined
below
are
for
normal
service
and
aver-
age
operating
conditions.
For extreme
load
conditions,
or
abnormal
operating
conditions,
service
more
frequently.
Keep
a
record
of
the
hours
of
operation
each
day
to
assure
servicing
at
the
proper
periods.
DAILY SERVICE
If
the
plant
is
operated
more
than
8 hours
daily,
perform
the
DAILY
SERVICB
operations
every
8 hours.
FUEL.-
If
the
plant
is
operated
on
gasoline
fuel,
check
the
fuel
gauge
often
enough
to
assure
a continuous
fuel
supply.
Do
not
fil1
the
tank
while
the
plant
is
running.
RADIATOR.-
Check
the
level
of
the
coolant
and,
if
necessary,
add
suffi-
cient
liquid
to
bring
the
level
up
to
within
one
or
two
inches
of
the
bottom
of
the
filler
neck.
In
freezing
weather,
if
a nonpermanent
type
antifreeze
is
used, check
the
protective
strength
of
the
coolant.
AIR
CLEANER.-
Check
the
oil
level
in
the
air
cleaner
cup
and add
suf~
ficient
oil
to
bring
it
to
the
indicated
level.
Clean
out
and
refill
the
oil
cup
if
dusty
conditions
prevail.
CRANKCASE
OIL
LEVEL.-
Check
the
oil
level
as
indicated
on
the
bayonet
type
oil
level
gauge. Do
not
allow
the
engine
to
operate
with
the
oil
level
close
to
the
low
level
mark on
the
gauge.
Add
sufficient
oil
of
the
proper
SAE
number
to
bring
the
level
to
the
upper
level
mark,
but
do
not
overfill
the
crankcase.
CLEk~ING.-
Keep
the
plant
as
clean
as
possible.
A
clean
plant
will
give
longer
and more
satisfactory
service.
WEEKLY SERVICE
If
the
plant
is
operated
more
than
50
hours a week,
perform
the
WEEKLY
SERVICE
operations
every
50
hours.
CRANKCASE
OlL.-
Add
crankcase
oil
as
neces'sary,
or
change
the
oil
after
50
operating
hours.
If
the
plant
has
been
operating
with
diluted
oil,
change
the
oil
after
25
hours
operation.
GENERAL
LUBlUCATION.-
Put a drop
of
light
lubricating
oil
on each
of
the
gOvernor
to
carburetor
link
ball
joints,
and
fill
the
distributor
oil
cup.
Put
several
drops
of
oil
in
the
oil
holes
at
each end
of
the
bat-
tery
qharging genera.tor, and
in
the
oil
hole
at.
the
forward end
of
the
starting
motor
of
the
direct
current,
battery
ignition
plant.
AIR
CLEA.'\lER.-
Clean
the
air
cleaner
filter
element and
cup
thoroughly
in
gasoline
or
other
suitable
solvent.
Allow
to
dry,
or
use compressed
air
.
to
dry.
Refill
the
cup
to
the
indicated
level
with
clean
oil
of
the
s~e
SilE
number
as
that
used
in
the
crankcase, except
as
noted
under
ABNORMAL
OPERATING
CONDITIONS.