Loading...
SERVICE
DIAGNOSIS
POSSIBLE
CAUSE
GENERATOR
OVERHEATING
Overloaded.
Reduce
load.
Brush
rig
out
of
position.
Be
sure
to
line
up marks. See Brush
Rig.
VOLTAGE
DROPS
UNDER
HEAVY
LOAD
Engine
lacks
power.
Poor compression.
Faulty
carburetion.
Restricted
air
cleaner.
Excessive choking.
Ca.rbon
in
cylinder.
Restricted
exhaust
line.
See remedies
for
engine
missing
under
heavy
load.
Tighten
cylinder
head and spark
plugs.
If
still
not'
corrected,
grind
the
valves.
Replace
piston
rings,
if
necessary.
Refer
to
MAINTEtIJANCE
AND
REPAIR.
Check
the
fuel
system. Clean,
ad-·
just
or
replace
parts
necessary.
Clean and
refill.
See
that
choke opens
properly.
Remove
carbon.
Clean
or
increase
the
size.
ENGINE
MISFIRES
AT
LIGHT
LOAD
Carburetor
idle
adjustment
set
wrong
or
clogged.
Spark
plug
gaps
too
narrow.
Intake
air
leak.
Faulty
ignition.
Uneven
compression.
Worn
intake
valve
stems
or
guides.
Adjust,
clean
if
needed.
Adjust
to
correct
gap,
0.02,5".
Tighten
or
replace
gaskets.
Clean,
adjust,
or
replace
breaker
points,
plugs,
condenser,
coil,
etc.,
or
retimeignition.
.
Tighten
cylinder
head and
spark
plugs.
If
still
not
corrected,
grind
valves.,
Replace
piston
rings,
if
necessary.
Replace
valves
or
guides.