EasyManuals Logo

Onan CCK Series User Manual

Onan CCK Series
108 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #25 background imageLoading...
Page #25 background image
INSTALLATION,
19
1
Phase,
3 Wire
-AC
Remote
On
single
phase,
three
wire
plants,
connecttheloqR,.,y-*esto
the
plant
by connecting the ground (white)
load
wire
to the
,eonlrol
box
terminal
marked
"M2". Connect one
of
the
';hot" ungroundeci'(bfack) load
wires
to
the
control
box
terminal
marked,
"Ml",and
conn~d.theremaining
"hot"
ungrounded (black) load,
wire
to
the
controlbo]i::tEirminal
marked
"M3". '
"""
Two 120
volt
circuits
are
available. One
circuit
across
"MP'
and "M2"
and another
circuit
across
'1M2"
and
"M3".
The load
on
each
i20volt
circuit
should not be
more
than
1/2
th~Sl!pacity
of
thepiant.
One 240 volt
circuit
is
available.
This
circuit
is
across
"Ml"
and "M3
1t
"M2"is
,not
used
with a 240 volt
circuit.
If only
240yolt
current
is
used,
the
full
ratedcaP!lcity
of
the
plant
may
be
used.
'
Both 120 volt
current
and 240 volt
current
may
beused
at
the
same
time.
However,
the
total
of
either
120 volt load
plus
1/2
the
240
volt
load
should not exceed
1/2
the
capacity
of
the
plant.
For
example:
a
total
of
2500
watts
isavaUable
oneach
120 volt
circuit
of a 5000
watt
single'
phase
3
wire
plant.
If2000
watts
ofcurrent~s
used
on
eith~r
120 volt
circuit,
only 1000
watts
of
240 volt
current
can
be
used
at
the
s~metime.
,To
de-
termine
the
current
available
on
each
120 volt
circuitwhenthe
240 volt
load
is
known,
subtract
the 246
volt
load
from
the plant:
rated
capacity
and
divide the
remainder
by two.
3
Phase,
3 Wire,:, AC
Remote
For
three
phase
current,
connect
onEiloadwire
to
each
of
the
three
generator
terminals
"M1"j "M2", and
"M3".If
a
testrtin
indicates
wrongrotation
of
3
phase
motors
in
the
load
circuit,:reverse
the
con-
nections
',at
any
two
generatorteI'minals.,
<-..
, ' . . , !
Single
phase
current
can
be
obtained between any two
terminals.
Three'
.such
single
phase
circultsare
th1;tsa.y~ilable:
"Mland
M2",
!1M!
and
Msn,
!1M3
,andM2!1.NotmorethanQ.n,~thirdthecapacityof
the
gen-
eratorisavailable
on
each
singlephase:~ircuit.
. " ,
If
both
single
and
three
phase
current
is
used
attl1e
.same
timet
use
.'
..
care
not
to
over-load
any. one
·ofthe
single
phase
cttcllJts.
Subtract
the·
amount
of
the
three
phase
load
from
the.
rated
capacity
of
the
generator.
Dividetheremaillder
:by
three,
todeterminethe
an)ountof
single
phase
load which may be connected to
eachofthel3ingleph~se
circuits.
4WirePl~nt
;..
AC.Remote
The
four
wire
plantJs
designed
toproduc;e.$ingleph;ise
cur~entof.
one
voltage,
and
three
phase
c,urreritotdifrerent'vol,~age.
As
indicated
on
the
plant nameplate,
thesingle.phasecurrel)t
is
the
lower voltage, and.

Other manuals for Onan CCK Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Onan CCK Series and is the answer not in the manual?

Onan CCK Series Specifications

General IconGeneral
Fuel TypeGasoline
Fuel SystemCarburetor
Frequency60 Hz
RPM1800 RPM
Starting SystemElectric or Recoil
Starting MethodElectric or Recoil Start
Voltage120/240V
Compression Ratio6.5:1
Ignition SystemBattery Ignition
PhaseSingle-phase

Related product manuals