INSTALLATION,
19
1
Phase,
3 Wire
-AC
Remote
On
single
phase,
three
wire
plants,
connecttheloqR,.,y-*esto
the
plant
by connecting the ground (white)
load
wire
to the
,eonlrol
box
terminal
marked
"M2". Connect one
of
the
';hot" ungroundeci'(bfack) load
wires
to
the
control
box
terminal
marked,
"Ml",and
conn~d.theremaining
"hot"
ungrounded (black) load,
wire
to
the
controlbo]i::tEirminal
marked
"M3". '
"""
Two 120
volt
circuits
are
available. One
circuit
across
"MP'
and "M2"
and another
circuit
across
'1M2"
and
"M3".
The load
on
each
i20volt
circuit
should not be
more
than
1/2
th~Sl!pacity
of
thepiant.
One 240 volt
circuit
is
available.
This
circuit
is
across
"Ml"
and "M3
1t
•
"M2"is
,not
used
with a 240 volt
circuit.
If only
240yolt
current
is
used,
the
full
ratedcaP!lcity
of
the
plant
may
be
used.
'
Both 120 volt
current
and 240 volt
current
may
beused
at
the
same
time.
However,
the
total
of
either
120 volt load
plus
1/2
the
240
volt
load
should not exceed
1/2
the
capacity
of
the
plant.
For
example:
a
total
of
2500
watts
isavaUable
oneach
120 volt
circuit
of a 5000
watt
single'
phase
3
wire
plant.
If2000
watts
ofcurrent~s
used
on
eith~r
120 volt
circuit,
only 1000
watts
of
240 volt
current
can
be
used
at
the
s~metime.
,To
de-
termine
the
current
available
on
each
120 volt
circuitwhenthe
240 volt
load
is
known,
subtract
the 246
volt
load
from
the plant:
rated
capacity
and
divide the
remainder
by two.
3
Phase,
3 Wire,:, AC
Remote
For
three
phase
current,
connect
onEiloadwire
to
each
of
the
three
generator
terminals
"M1"j "M2", and
"M3".If
a
testrtin
indicates
wrongrotation
of
3
phase
motors
in
the
load
circuit,:reverse
the
con-
nections
',at
any
two
generatorteI'minals.,
<-..
, ' . . , !
Single
phase
current
can
be
obtained between any two
terminals.
Three'
.such
single
phase
circultsare
th1;tsa.y~ilable:
"Mland
M2",
!1M!
and
Msn,
!1M3
,andM2!1.NotmorethanQ.n,~thirdthecapacityof
the
gen-
eratorisavailable
on
each
singlephase:~ircuit.
. " ,
If
both
single
and
three
phase
current
is
used
attl1e
.same
timet
use
.'
..
care
not
to
over-load
any. one
·ofthe
single
phase
cttcllJts.
Subtract
the·
amount
of
the
three
phase
load
from
the.
rated
capacity
of
the
generator.
Dividetheremaillder
:by
three,
todeterminethe
an)ountof
single
phase
load which may be connected to
eachofthel3ingleph~se
circuits.
4WirePl~nt
;..
AC.Remote
The
four
wire
plantJs
designed
toproduc;e.$ingleph;ise
cur~entof.
one
voltage,
and
three
phase
c,urreritotdifrerent'vol,~age.
As
indicated
on
the
plant nameplate,
thesingle.phasecurrel)t
is
the
lower voltage, and.