EasyManua.ls Logo

Onkyo TX-RZ830 - Service Mode; How to enter to service mode.; How to exit the service mode.; How to clear Protect Data

Onkyo TX-RZ830
192 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Service Mode
5 4 3
2
1
6
D
C
A
B
D
C
A
B
5 4 3
2
1
6
COMMON
How to enter to service mode.
Step1 :
[DIMMER] + [ON/STANDBY] x 2
Step2 :
[SETUP] or [HOME]
Step3:
Follow this Tree operation for each service mode.
How to exit the service mode.
Please press the [ANY INPUT SELECTOR]
How to clear Protect Data
Step1:
Select “ProtectDataCLR” from this tree
Step2:
Press [ENTER] button
After display “DATA Cleared!”, It will be data reset and go to normal mode.
Enter Service mode
M1.xx / xxxxxAEx
The version of main microprocessor.
(displayed only for 3 seconds)
1. Service
Normal display
Protect Data CLR
Clear:[ENTER]
DataCleared!