V1.1-ENG
3 www.onlab.com.tr
CABLE CONNECTIONS AND PROPERTIES
It is recommended to use 3x0,3mm
2
stranded wire to connect GRID connector.
Cable that will be used to connect MOTOR connector should be 3x0,5 mm
2
stranded wire and
cable length should be smaller than or equal to 1,75m.
Motor cable connection must be done with the correct order according to the colors given
below. Otherwise, the device will give an error and cannot move the door.
Colors of Motor Cable
U
V
W
:
:
Blue
Red
Cable that will be used to connect ENCODER should be 8x0,22mm
2
stranded wire and cable
length should be smaller than or equal to 1,75m. It is strongly advised to use shielded cable
for encoder connection and shield of this cable can be connected to PE terminal if it is needed.
Encoder cable connection must be done with the correct order according to the colors given
below. Otherwise, the device will give an error and cannot move the door.
Colors of Encoder Cable
+5V
GND
A+
:
:
Red
Brown
A-
B+
B-
Z+
Z-
Cable that will be connected to the INPUT and OUTPUT terminals can be in various lengths
that can be adjusted according to the application and place it is mounted.