13
Spike/Surge protection
Version Continuous Single pulse 8/20us
Voltage Vrms Imax Joules
100/110/120V 175V 6,000A 1050
220/230/240V 385V 6,000A 1050
Audible Alarm
Battery discharge at power failure
Beep every 2 seconds
Battery approaches final discharge
Beep every half second
Overload
Continuous buzzer
UPS faulty
Continuous buzzer
Battery and Charger
Battery type: Maintenance-free sealed-lead acid. Recharge time 6 to 8 hours
typical from total discharge. (The UPS may be used immediately after
discharge but will provide shorter backup time)
Battery Specifications
ES550C ES800C ES1000C ES1500C
ES1000C
-RM
ES1500C
-RM
DC
voltage
12V 12V 24V 24V 24V 24V
Type
12V
7.2AH
12V
34W
12V
7.2AH
12V
34W
12V
7.2AH
12V
34W
Quantity 1 1 2 2 2 2
Recharge
time
4 Hours 4 Hours 4 Hours 4 Hours 4 Hours 4 Hours
4.2 Mechanical Specifications:
Dimensions Weight (Kg)
Product Name
L × W × H (mm)
Net Shipping
ES550C
322x102x165 7.1 7.4
ES800C
322x102x165 7.1 7.4
ES1000C
378x140x201 13.7 14.9
ES1500C
378x140x201 16.3 17.5
ES1000C-RM
426x428x84 17.2 20.2
ES1500C-RM
426x428x84 17.5 20.5