Users Guide
Durable Series
Models DS1000B, 1500B, 2000B, 3000B
DS1000B-RM, 1500B-RM, 2000B-RM,
3000B-RM

Questions and Answers

  • E
    erobinsonAug 17, 2025
    What to do if OPTI-UPS DS2000B is on battery?
    • B
      Bianca CarrollAug 17, 2025
      If your OPTI-UPS UPS is operating on battery power, it's crucial to save your data promptly and perform a controlled shutdown of your systems to prevent data loss or corruption.
  • S
    Stephen JohnsonAug 20, 2025
    Why is my OPTI-UPS DS2000B showing Output Overload?
    • V
      Victoria JohnsonAug 20, 2025
      The OPTI-UPS UPS is overloaded because the connected equipment needs more power than the UPS can supply in Line Mode. To resolve this, turn off the least important equipment. If this solves the problem, the UPS will switch from bypass back to normal operation.
  • K
    Kimberly HernandezAug 22, 2025
    What to do if my OPTI-UPS UPS displays an Over-Temperature warning?
    • T
      Troy RobinsonAug 23, 2025
      If your OPTI-UPS UPS displays an Over-Temperature warning, ensure that the unit’s fans and vent holes are not blocked. Also, verify that the surrounding temperature is not above 40 degree C. If these steps don't solve the problem, contact your service representative.
  • L
    Luke CarlsonAug 26, 2025
    What to do if OPTI-UPS DS2000B has a Bus Fault?
    • E
      erica17Aug 26, 2025
      If your OPTI-UPS UPS has a Bus Fault (High internal DC bus Voltage), turn off the protected loads, turn off the UPS, and call your local dealer for assistance.
  • M
    Maxwell HamiltonAug 28, 2025
    What to do if my OPTI-UPS UPS displays an Over-Charge error?
    • B
      Brenda JenningsAug 28, 2025
      If your OPTI-UPS UPS displays an Over-Charge error, turn off the protected loads and turn off the UPS. Then, contact your local dealer for further assistance.
  • K
    Kaitlyn NewmanAug 31, 2025
    What does it mean when my OPTI-UPS DS2000B UPS says 'Site wiring Fault'?
    • Y
      yangantonioAug 31, 2025
      A 'Site wiring Fault' on your OPTI-UPS UPS indicates voltage detected between Neutral and Ground. This could mean the UPS mains connector polarity is wrong; try rotating the connector (Schuko). It can also mean the UPS is installed to a mains supply without ground. See page 15 on how to disable the site wiring alarm.
  • M
    Mr. Tony CochranSep 2, 2025
    What to do if OPTI-UPS UPS reports a Charger Failure?
    • C
      Cindy MccormickSep 2, 2025
      If your OPTI-UPS UPS indicates a Charger Failure, you should contact your local dealer for support.
  • A
    andersonfernandoSep 5, 2025
    What to do if my OPTI-UPS DS2000B indicates a Battery Test?
    • C
      chintonSep 5, 2025
      No action needed. The OPTI-UPS UPS will return to normal operation when it successfully completes the battery test.
  • C
    Crystal RosarioSep 8, 2025
    What to do if OPTI-UPS DS2000B reports Output Short?
    • S
      Sharon DoyleSep 8, 2025
      If your OPTI-UPS UPS reports an Output Short, contact your local dealer for assistance.
  • K
    kayersSep 12, 2025
    What to do if OPTI-UPS UPS indicates High output Voltage?
    • H
      Hector Sanchez DDSSep 12, 2025
      If your OPTI-UPS UPS indicates High output Voltage, contact your local dealer for assistance.

Summary

Limited Warranty Details

Warranty Limitations and Disclaimers

Implied Warranties and Damages Exclusion

Limits implied warranties and excludes specific types of damages.

Important Safety Instructions

General Safety Precautions

Provides critical safety instructions for UPS operation and maintenance.

Installation and Safety

Storage, Transportation, and Installation Safety

Covers safe handling, storage, and installation procedures.

Permitted User Operations

Specifies the limited operations users are allowed to perform.

Installation Details

Environment Requirements

Specifies environmental concerns for safe installation and operation.

Rack-mounted Installation and Rear Panels

Rear Panel Views (Continued)

Connection to Mains and Loads

Connection Procedure

Provides instructions for connecting the UPS to mains and loads.

Computer and Alarm Connections

Starting and Shutting Down the UPS

Control Panel Functions

UPS Configurations

Troubleshooting

Alarm Indicators

Lists audible alarms and their corresponding causes.

Trouble Shooting Table

Provides common UPS issues, alarms, and recommended actions.

Maintenance

Replacing Batteries

Step-by-step tutorial for replacing the UPS batteries.

Technical Specifications

100;110;120 V Specifications

Technical data for 1000-3000 VA models at 100/110/120V.

220;230;240 V Specifications

Technical data for 1000-3000 VA models at 220/230/240V.

19 Rack-mount Model (100;110;120 V) Specs

Technical data for 19" rack-mount models at 100/110/120V.

Technical Specifications (Continued)

19 Rack-mount Model (220;230;240 V) Specs

Technical data for 19" rack-mount models at 220/230/240V.

Technical Specifications (Continued)

220;230;240 V Model Specifications

Details specifications for 220/230/240V models.

Battery Packs

Provides details on battery types, quantities, and backup times.

19 Rack-mount Model (2 U) Battery Packs

Details battery packs for 19" Rack-mount Model (2U).

OPTI-UPS DS2000B Specifications

General IconGeneral
CategoryUPS
Capacity2000VA / 1200W
Output Power1200 W
Output Frequency50/60 Hz
Number of Batteries2
Communication PortsUSB
Form FactorTower
Transfer Time4 ms
Battery TypeSealed Lead Acid
Data Line ProtectionRJ-45
Weight12 kg