PUTTING INTO OPERATION
Inverter
The OptiClimate inverter models adjust the cooling capacity to the need. Non-Inverter models operate on
an on / off basis, while the inverter models run the compressor harder/ softer when more or respectively
less cooling capacity is required. This provides an even more stable climate and prevents the frequent trip-
ping of the unit in case of over capacity.
The inverter function operates on the basis of the fan speed. This means that the fan can be set to automatic
in the day position, using the remote control (FN). If the fans are set at a fixed rate, the inverter
function is switched off and the compressor also runs at a fixed rate. (resp. low / middle / high). For the
night position, we recommend that you always use the low setting.
4) Temperature setting
Users can set the temperature from 16°C to 34°C.Pressing the or key will show the set temperature SET
TEMP on the display. By pressing it once more, you can set the required temperature. The set temperature
will be saved and stored after 3 seconds. Switching between day and night temperatures is done using the
[M] mode key.
5) Time setting [T] key
Press the [T] key once to select the hours and then press the or key to change the hours. Press the [T] key
again, and the minutes will flash and then press the or key to change the minutes. Now press the [R] key
to confirm the hours and minutes that you entered.
Automatic Light Cell setting (Day /Night programme)
The automatic moisture meter in the pro3 series has a light cell, which switches to the day mode when it sees
the light is on and to the night mode when the light is off. Only the Day/Night temperatures have to be set,
the rest is done automatically.
If you want to set the unit manually, the automatic light cell can be switched off and the unit will operate ma-
nually. By pressing the [M] key for 3 seconds, the mode switches from light cell to manual. By pressing the
[M] key again for 3 seconds, the mode switches from manual to light cell. If the automatic light cell
is activated, the display shows an A.
7) Timer Setting (DAY/NIGHT programme)
As a general rule, we recommend using the automatic light cell mode. Only set the timer if you do not want
to work with the light cell!
This function can be used to set the DAY/NIGHT programme. The programme restarts every day regardless
of which day it is. If the timer is set, the display will show the clock icon next to the time:
Press the [T] key for 2 seconds. When “---”, ON becomes visible, you can change the timer setting. Pressing
the or key will allow you to set the hours of the ON time. Pressing the [T] key again will allow you to set
the minutes of the ON time. The ON time is the time that the unit will start to cool.
Pressing the [T] key again will allow you to set the OFF time. The OFF time is the time that the unit will start
to heat/ dehumidify. If the timer is not set yet, the display will show “--:--” or the time that was already set.
Note: It is important to note that when the Timer setting is programmed the automatic light cell mode is
deactivated. Therefore, program a Timer only if you want to use advanced options. The Timer mode is
active when a clock icon appears in the display.