Baery Tips!
The baery indicator on your control panel will show how much energy is le in your baery bank. It is important to note that
it does NOT explicitly show how much useable power is le in your baeries.
You have a 300 amp baery system. AGM baeries are able to reliably put out over 12.0v of power for 50% of their capacity.
Most 12v appliances will require a 12volt output from the baeries to work. This means you 150 usable amp hours from a
fully charge set of baeries. The indicator on your control panel will show you how much total energy you have in your enre
baery bank. This means that when your indicator shows 50% you have used all of the usable power within your baery
bank. If you connue to drain power from your baeries beyond this point can and will most likely cause damage to your
baery bank.
AGM baery lifespans are longer when they remain at full charge. Frequently discharging your baeries and leaving them
empty will accelerate the degradaon process of your baeries and reduce their lifespan. The NOCO Genius charger
installed in your OP15 will control the amount of charge delivered to your baeries so that they do not over charge, therefore
you can leave your OP15 plugged in at all mes when at home.
If you are not keeping your OP15 plugged in whilst at home we recommend that you disconnect your baeries to maintain
good baery health. Please see the *care and maintenance secon for more informaon on this topic.
The CO/LP alarm is wired directly to the baeries. This means that turning the power to the OP15 o on the control panel will
NOT shut power o to the CO Alarm. Please follow the winterizaon process for baery care to ensure you are fully
disconnecng the baeries during long periods of storage.
Always set your fridge to LO before heading out on your trip. This will use less power from your baery and allow you
longer o-site camping.
Solar Power
There are three 100 wa solar panels mounted to the roof of the OP15 with a 30amp solar
charge controller installed. During the day with adequate sunlight, the solar panels will
automacally trickle charge your baeries. We recommend reading the user manual for your
solar panels & charge controller in full to understand the capabilies and sengs for the
solar panels and charge controller.
12 Volt Baery Power cont.
On the control panel you will nd the main 12v ON/OFF switch. There are sepa-
rate switches for the following 12volt operated appliances and systems in the
OP15: Fridge, Sockets, Lights, Water Pump.
The OP15 has two 12v outlets for the interior TV hookup, two for the exterior TV
hookup and one exterior 12v socket by the kitchen. The internal and external
lights for your OP15 are all 12v LED. They can all be switched on or o inde-
pendently either on the light itself or on via a switch in the OP15.
Exterior
Rear Light
Motorized
Step
Main
Interior Light
Exterior Door
Handle Light
Exterior
Prep-deck Light
120 VOLT & 12 VOLT POWER cont.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Opus Off-Road Camper OP15 and is the answer not in the manual?

Opus Off-Road Camper OP15 Specifications

General IconGeneral
BrandOpus
ModelOff-Road Camper OP15
CategoryUtility Vehicle
LanguageEnglish

Related product manuals