Water tanks
Issue: Water pump is running when all faucets & valves are closed
Troubleshoot: Leak in the system. Idenfy leaking ng and aempt to ghten the ng (usually hand-ght should be sucient
without the need for a wrench which could potenally over-ghten and damage the system. If sll leaking, disconnect and check
for debris or degrading within the ng.
Issue: Water pump running but no water at faucets
Troubleshoot: No water in tanks? Check for faulty sensor that could be misleading you to think that there is water in the tanks.
Possibly the sensor needs cleaning or replacing.
Check the tank selector valve is directed at the correct tank (or both tanks are chosen). See page 18.
Propane System
Issue: Stove top won’t stay ignited.
Troubleshoot: Press and hold the ignion/ dial for 10 seconds to overcome the safety thermocouple.
Consider the outside temperature; cold weather can cause the BTU of propane to drop. This can impact overall performance of the
propane system. Keep your propane tanks full during cold weather and check other appliances that might also be using propane at
the me.
TROUBLESHOOTING
New Trailer Maintenance
Trailer breaks
Your electric drum breaks require a break-in period to achieve full and proper performance. This applies when you rst receive
your new OP15 then aer new parts are installed as part of your maintenance schedule. Your OP15 brakes should be adjusted
aer the rst 200 miles then every 3000 miles aer that. We highly recommend that all break adjustments, maintenance and
servicing is carried out by a qualied technician at your OPUS dealership.
CAUTION! You may need to adjust your brakes more frequently dependent on variaons in cargo weights.
Suspension, Wheel and Hitch Bolts
Aer your rst 50 miles then 500 miles aer that please check the suspension bolts, wheel nuts
and hitch bolts to ensure that they have maintained their ghtness. This check should be
completed with a torque wrench to 100 lbs. When ghtening wheel nut lugs, please ghten
bolts in a star-paern order as indicated in the diagram to the right. Aer that, check your bolts
every 2000 miles and always before an extended trp.
Potable Water Tank
Please be sure to ush and sanize your potable water tank before rst use.