20
EN
3 Replace the fi lter and press and hold SLEEP/RESET reset the fi lter counter.
TROUBLESHOOTING
Effective operating temperature
The device effectively dehumidifi es at a temperature ranging from 5 ° C to 35 ° C.
If the ambient temperature is lower or higher than the effective operating
temperature, the dehumidifi er will stop working.
At an ambient temperature in the range of 5 ° C to 16 ° C, the compressor of the
device performs automatic defrosting at certain intervals.
During such defrosting, the compressor will stop, but the fan will still run.
BEFORE CONTACTING SERVICE
Before contacting a professional service, read the following fault overview, which
contains common cases that are not a symptom of a fault.
Problém Possible cause
The device does not work. No power
The Water Full indicator
ashes
The ambient temperature
is below 5 °C/above 35 °C.
Malfunction Not clogged with air
lter?
Suction is not blocked
or blowing?
No air supply
Is the fi lter clogged?
Solution
Connect the cord to the
working el. sockets.
Pour out the water tank
and reinsert it correctly.
Protective function of the
device. The device does not
work at this temperature.
Clean the air fi lter
according to the instructions.
Clean the air fi lter
according to the instructions.
Wash the fi lter.