25
Operations
Manual programming
If you want to store the frequency of 403.0250 at 03 channel with 40-42 small
range (40-42).
1. Press the 200RX button
2. press "PRI/LO" button until "40-42"is briey displayed
3. Rotary channel select to "03" channel.
4. Press and hold the "PRI/LO" button 2 seconds. "400" rst digit should
blinking.
5. Rotary channel switch to select "403".
6. Press The "PRI/LO" button, next 2 digits will be blinking for the next
frequency digits.
7. Rotary channel switch to select "0250".
8. To store the required frequency, briey press the "ID/CAL".
9. Press the 200RX button to exit.
Automatic Programming
1. Press the power button to turn the radio on.
2. Briey press the 200RX button.
3. Rotary channel select to the required channel. Example channel "04".
3. Briey press SC/MEM button (OS is displayed).
4. Autoscan will commence in 2 to 3 seconds.
5. To store the required frequency, briey press the ID/CAL button.
The stored channel will appear with "M" on the LCD.
6. Press the 200RX button to exit.
Factory reset
If the radio's display locks up or stops functioning properly, you might need to
reset your UHF radio.
Caution: this procedure clears all the information you have stored in your UHF radio.
Before you reset your UHF radio, try turning it off and on again. If your UHF radio
is still not functioning correctly you may need to reset the UHF radio.
While holding the F/DPX button, turn the UHF radio on. INITI AL will be displayed
for 1 to 2 seconds, the radio will then return to its original display.