ID Parameter name Setting range
Factory
setting
Update
*1
Base settings
Driver user name Up to 16 characters A
1820 Speed, torque limiting command selection
0: Digital setting
1: Analog setting for the speed
No.1, and digital setting for others
2: Analog setting for speed, and
digital setting for torque limiting
3: Digital setting for speed, and
analog setting for torque limiting
0 C
2033 Speed reduction ratio 100 to 9999 100
A2038 Speed reduction ratio digit setting 0: ×1, 1: ×0.1, 2: ×0.01 2
2039 Speed increasing ratio 1.00 to 2.00 1.00
450 Motor rotation direction
0: Positive direction=CCW
1: Positive direction=CW
1 C
Speed, torque limiting
adjustment
2085 Speed upper limit 50 to 4000 [r/min] 4000
B
2086 Speed lower limit 50 to 4000 [r/min] 50
1821 Analog operation speed command gain 0 to 4000 [r/min/V] 850
A
1822 Analog operation speed command oset -2000 to +2000 [r/min] 0
1823 Analog torque limiting gain 0 to 300 [%/V] 65
1824 Analog torque limiting oset -150 to +150 [%] 0
1825 Analog torque limiting maximum value 0 to 300 [%] 300
Alarm/information setting
384 Overload alarm detection time 0.1 to 40.0 [s] 30.0 A
414 Prevention of operation at power-on alarm 0: Disable, 1: Enable 1
C
413 Electromagnetic brake function at alarm
*2
0: Lock after coasting to a stop
1: Lock immediately
1
447 INFO auto clear
0: Disable
1: Enable
1
A
416 Driver temperature information 40 to 85 [°C] 85
418 Speed information 50 to 5000 [r/min] 5000
422 Load information 10 to 300 [%] 300
425 Overvoltage information 280 to 440 [V] 435
426 Undervoltage information 120 to 280 [V] 120
431 Tripmeter information
0: Disable
1 to 999,999,999 (1=0.1 kRev)
0
432 Odometer information
0: Disable
1 to 999,999,999 (1=0.1 kRev)
0
438 Main power supply time information
0: Disable
1 to 999,999,999 [min]
0
439 Main power supply count information
0: Disable
1 to 999,999,999 [times]
0
1954 INFO action (Driver temperature information (INFO-DRVTMP))
*3
0: INFO action is not applied
1: INFO action is applied
1
1956 INFO action (Overvoltage information (INFO-OVOLT))
*3
1957 INFO action (Undervoltage information (INFO-UVOLT))
*3
1959 INFO action (Load information (INFO-LOAD))
*3
1960 INFO action (Speed information (INFO-SPD))
*3
*1
Timing to update
A: Update immediately (Recalculation and setup are immediately executed when the parameter is written.)
B: Update after operation stop (Recalculation and setup are executed when the operation is stopped.)
C: Update after executing conguration or turning on the power again
(Recalculation and setup are executed after the conguration is executed or the power is turned on again.)
D: Update after turning on the power again (Recalculation and setup are executed after the power is turned on again.)
*2
Only drivers for electromagnetic brake motor are available.
*3
It is enabled for drivers with software version 3.00 or later.

Table of Contents